Clare Controls CLIQ-HLE Manual De Usuario

Descargar
Página de 3
2 / 3 
 
Doc ID 2014-12-613 • REV 06 
Note:
 The CobraNet port is preset with the static IP 
address 172.30.100.1. All CobraNet devices used on the 
same subnet must use an address from 172.30.100.2 to 
172.30.100.254.  
7.  Use an Ethernet cable (not included) to connect to your 
data network switch to the port labeled “Ethernet.” See 
Figure 2, item 6. 
Notes 
  The Network port is preset to DHCP. If you are using 
the Streaming Media server in your project, a fixed IP 
address is not required and should be configured as 
“localhost.” 
  If you are using a device, such as an RTI remote that 
requires the controller to have a static IP, you must set 
the static IP using a MAC/DHCP reservation on the local 
router. 
8.  Connect relay contacts (e.g., garage door contacts) to the 
6-pin terminal connector, and then insert the terminal 
connector into the port labeled “Relay.” See Figure 2,  
item 7. 
9.  Screw the Z-Wave antenna or optional Z-Wave antenna 
extender into the Z-Wave port. See Figure 2, item 8. 
Figure 1: CLIQ.host front  
                                                                                                                                                                                                         
(1)  LED – Illuminates when unit is powered on  
 
Figure 2: CLIQ.host rear connections 
                                                                                                                                                                                                         
(1)   RS-232 (2 ports) 
(2)   IR Outputs 
(3)   USB ports 
(4)   I/O 
(5)   CobraNet 
(6)   Ethernet 
(7)   Relay 
(8)   Z-Wave antenna 
(9)   Power – 12 VDC 
 
 
RS-232 port pinouts 
If you are using your own RJ12 cable (rather than the one 
supplied), ensure your RJ12 cable connector pinouts match 
the pinouts on the RS-232 ports, as shown in Figure 3. 
Figure 3: RS-232 ports with pinouts 
 
 
Powering the CLIQ.host 
Plugging in the power adapter automatically turns on the 
CLIQ.host and starts the boot process.  
To connect power to the CLIQ.host: 
1.  Plug one end of the power adapter into a power receptacle 
on the back of the CLIQ.host labeled “12vdc.” See  
Figure 2, item 9. 
2.  Check the LED on the front of the CLIQ.host. It illuminates 
blue when the device is receiving power. See Figure 1, 
item 1. 
Time, date, and time zone 
Your CLIQ.host controller automatically detects and sets its 
time, date, and time zone when you connect it to your data 
network. CLIQ.host uses NTP and synchronizes the date and 
time at boot up and periodically throughout the day. 
Configure, test, and deploy a project 
Refer to the Fusion Configuration Tool Administrator Guide 
(Doc ID 069) for instructions on creating, testing, and deploying 
a project. When you deploy the project from Fusion, it will 
deploy to the CLIQ.host.  
Adding the rubber foot covers 
To prevent the unit from sliding, use the four rubber foot covers 
included with your CLIQ.host.  
To add the rubber foot covers: 
 
Peel each foot cover from the paper backing and place 
one on each foot on the bottom of the CLIQ.host. 
 
 
 
RS232
IR Outputs
USB
I/O
CobraNet
Ethernet
Relay
#1
#2
12vdc
Networks
#1
#2
1
2
3
4
5
6
1
2
v
d
c
G
n
d
#
3
 
#
1
#
2
1
2
v
d
c
G
n
d
#
4
N
N
O
C N
N
O
(1)
(2)
(3)
(4)
(5)
(6)
(7) (8)
(9)
RS232
#1
#2