Clare Controls CLIQ-HLE Manual De Usuario
2 / 3
Doc ID 2014-12-613 • REV 06
Note:
The CobraNet port is preset with the static IP
address 172.30.100.1. All CobraNet devices used on the
same subnet must use an address from 172.30.100.2 to
172.30.100.254.
same subnet must use an address from 172.30.100.2 to
172.30.100.254.
7. Use an Ethernet cable (not included) to connect to your
data network switch to the port labeled “Ethernet.” See
Figure 2, item 6.
Figure 2, item 6.
Notes
•
The Network port is preset to DHCP. If you are using
the Streaming Media server in your project, a fixed IP
address is not required and should be configured as
“localhost.”
address is not required and should be configured as
“localhost.”
•
If you are using a device, such as an RTI remote that
requires the controller to have a static IP, you must set
the static IP using a MAC/DHCP reservation on the local
router.
the static IP using a MAC/DHCP reservation on the local
router.
8. Connect relay contacts (e.g., garage door contacts) to the
6-pin terminal connector, and then insert the terminal
connector into the port labeled “Relay.” See Figure 2,
item 7.
connector into the port labeled “Relay.” See Figure 2,
item 7.
9. Screw the Z-Wave antenna or optional Z-Wave antenna
extender into the Z-Wave port. See Figure 2, item 8.
Figure 1: CLIQ.host front
(1) LED – Illuminates when unit is powered on
Figure 2: CLIQ.host rear connections
(1) RS-232 (2 ports)
(2) IR Outputs
(3) USB ports
(4) I/O
(5) CobraNet
(2) IR Outputs
(3) USB ports
(4) I/O
(5) CobraNet
(6) Ethernet
(7) Relay
(8) Z-Wave antenna
(9) Power – 12 VDC
(7) Relay
(8) Z-Wave antenna
(9) Power – 12 VDC
RS-232 port pinouts
If you are using your own RJ12 cable (rather than the one
supplied), ensure your RJ12 cable connector pinouts match
the pinouts on the RS-232 ports, as shown in Figure 3.
supplied), ensure your RJ12 cable connector pinouts match
the pinouts on the RS-232 ports, as shown in Figure 3.
Figure 3: RS-232 ports with pinouts
Powering the CLIQ.host
Plugging in the power adapter automatically turns on the
CLIQ.host and starts the boot process.
CLIQ.host and starts the boot process.
To connect power to the CLIQ.host:
1. Plug one end of the power adapter into a power receptacle
on the back of the CLIQ.host labeled “12vdc.” See
Figure 2, item 9.
Figure 2, item 9.
2. Check the LED on the front of the CLIQ.host. It illuminates
blue when the device is receiving power. See Figure 1,
item 1.
item 1.
Time, date, and time zone
Your CLIQ.host controller automatically detects and sets its
time, date, and time zone when you connect it to your data
network. CLIQ.host uses NTP and synchronizes the date and
time at boot up and periodically throughout the day.
time, date, and time zone when you connect it to your data
network. CLIQ.host uses NTP and synchronizes the date and
time at boot up and periodically throughout the day.
Configure, test, and deploy a project
Refer to the Fusion Configuration Tool Administrator Guide
(Doc ID 069) for instructions on creating, testing, and deploying
a project. When you deploy the project from Fusion, it will
deploy to the CLIQ.host.
(Doc ID 069) for instructions on creating, testing, and deploying
a project. When you deploy the project from Fusion, it will
deploy to the CLIQ.host.
Adding the rubber foot covers
To prevent the unit from sliding, use the four rubber foot covers
included with your CLIQ.host.
included with your CLIQ.host.
To add the rubber foot covers:
•
Peel each foot cover from the paper backing and place
one on each foot on the bottom of the CLIQ.host.
one on each foot on the bottom of the CLIQ.host.
RS232
IR Outputs
USB
I/O
CobraNet
Ethernet
Relay
#1
#2
12vdc
Networks
#1
#2
1
2
3
4
5
6
1
2
v
d
c
G
n
d
#
3
#
1
#
2
1
2
v
d
c
G
n
d
#
4
N
N
O
C N
N
O
(1)
(2)
(3)
(4)
(5)
(6)
(7) (8)
(9)
RS232
#1
#2