Unique Broadband Systems Ltd. DRU1KW Manual De Usuario

Descargar
Página de 176
 
 Chapter 
Installation 
 
SX03-20000-01-M01 3-10 
3.6.2 
Installation Surface 
 
The load bearing strength of the roof or floor where the repeater cabinets will be placed 
should be taken into consideration.  The repeater cabinets weigh approximately 
2200 lbs. 
combined and rests on an area of 
7.85 square feet
 of roof or floor space. 
 
Before installing the repeater cabinets, check the installation surface structure, flatness and 
suitability. 
 
 
3.6.3 
Repeater Cabinet Positioning 
 
 
Over tipping the repeater may cause it to fall over, resulting in personal 
injury or loss of life. 
 
  The methods described in Section 3.6.1 can be used to move the repeater cabinets 
to the required installation location. 
  Unbolt the cabinet’s feet from the pallet before attempting to remove it from the 
pallet. 
  Position the repeater cabinets according to the site drawings (if available). 
  The repeater cabinet must be bolted to a load frame, to the roof surface, or to the 
floor at all sites to prevent possible tipping.  Please see Figure 3-5 for mounting hole 
locations.