CAPSTONE INDUSTRIES INC VANITY2 Manual De Usuario

Descargar
Página de 8
PARTS & SPECIFICATIONS
TOOLS REQUIRED
Phillips Screw Driver
Flat Head Screwdriver
Drill (Option 2 only)
Drill Bit 7mm (9/32”) (Option 2 only)
Ladder
Level
Safety Goggles
HARDWARE INCLUDED
AA 
2 – Mounting Plate Screws (Pre-installed)
BB   
2 – #8-32 x 1” Electrical Box Mounting Screws (Option 1)
CC 
2 – Wire Nuts
DD 
2 – Capstone Quick Connector (1 Pre-wired; 1 Loose)
EE 
2 - #4 x 1” Self-Tapping Wall Mounting Screws (Option 2)
FF 
2 – Plastic Wall Anchors (Option 2)
GG 
1 – White Cleaning Cloth
DIAGRAM
Light Fixture
Mounting Plate
Electrical Box Screw Hole (Option 1)
Wall Mounting Screw Holes (Option 2) 
Ground Screw (Green, Pre-installed) 
AA 
Mounting Plate Screws (Pre-installed)
ON/OFF Rocker Switch
Electrical Box (not included)
AA BB
EE
CC
FF
DD
GG
A
D
B
AA
AA
E
F
G
INSTALLATION
 
 IMPORTANT: This fixture has two installation options. 
OPTION 1 – ANCHOR TO AN ELECTRICAL BOX
OPTION 2 – ANCHOR TO A WALL
Both OPTION’s require powering the fixture using a standard 4” octagonal recessed electrical box (G). 
 WARNING: Consult a qualified electrician if you have any electrical questions.
 WARNING: Before starting installation of this fixture or removal of an existing fixture disconnect the power 
by turning off the circuit breaker or by removing fuse at fuse box.
 
 IMPORTANT: Notice the position of cutouts on the Mounting Plate. Cutouts must be positioned correctly 
for proper mounting.
Bottom
C