4. Block Diagram
< Fig.1 Hardware Block Diagram >
5. Absolute Maximum Ratings
Caution : The specifications in Table 1 define levels at which permanent damage to
the device can occur. Function operation is not guaranteed under these conditions.
Operating at absolute maximum conditions for extend periods can adversely affect the
long-term reliability of the device.
Parameter
Min
Max
Unit
Storage Temperature
-10
+80
Storage Humidity (40
)
-
90%
%
< Table 1 Absolute Maximum Ratings > . Other conditions
1) Do not use or store modules in the corrosive atmosphere, especially where chloride
gas, sulfide gas, acid, alkali, salt or the like are contained. Also, avoid exposure to moisture.
2) Store the modules where the temperature and relative humidity do not exceed 5 to 40
 and 20 to 60%.
3) Assemble the modules within 6 months.
Check the soldering ability in case of 6 months over.