5.5   Logging into AccessLink 
5.5.1   Logging into AccessLink via SSH 
  The default IP address of the AccessLink is 192.168.9.10. 
  Set your computer's IP address in the range '192.168.9.xx', xx being in the range (2-254 
except 10 when using default IP). 
  Connect the AccessLink with an Ethernet cable to the newly configured port and power 
ON. 
  Download and install the program "PuTTY" (or any ssh client) on the computer you just 
assigned the new IP address to. 
  Connect to the default IP 192.168.9.10 on port 22 using the ssh client. 
Note: If the IP address was changed using the USB method, use the IP address that was 
assigned to the AccessLink instead of the default IP. 
  When the unit is done booting up, log in as "root." 
o  Password for "root:" "veeone" 
o  It is recommended to change the "root" password by typing the following 
command and following the on-screen instructions: "passwd" 
5.5.2   Logging into AccessLink via Serial Port 
  The serial cable required for a proper connection is a female-to-female, pin-to-pin cable, 
which should be provided in the package. 
◦  Serial connection settings are: 
▪  Speed 115200 
▪  Data bits: 8 
▪  Stop bits: 1 
▪  Parity: None 
▪  Flow control: None 
◦  Connect and switch the device on and wait for it to boot. 
  When the unit is done booting up, log in as "root." 
◦  Password for "root" is “veeone” 
It is recommended to change the root password by doing this command and following the on-
screen instructions: "passwd"