Ever Sinline XL Rack 3000VA/2100W W/SLXLRM-003K00/00 Manual De Usuario

Los códigos de productos
W/SLXLRM-003K00/00
Descargar
Página de 3
SINLINE XL Rack
1800, 2200, 3000
2200VA/1540W
3000VA/2100W
~150 - 280V (~160 - 265V) ± 2%
45 - 55Hz  1Hz
± 
~172 - 280V (~184 - 265V) 
 
± 2%
<3 ms
sinus
~230V ± 5%
50Hz   1Hz
±
LC
0 ms
6 x IEC 320 C13
+ / +
RS 232, USB, 
network adapter (optional)
PowerSoft Personal
o
+10 C - +35 C / 
o
o
o
0 C - +45 C
up to 1000m
line-interactive (VI)
Rack 19’’ 3U
SINLINE XL 1800
Rack
SINLINE XL 2200
Rack
SINLINE XL 3000
Rack
1800VA/1260W
132 x 500 x 400
4 x 12V 9Ah
3h
39 kg
2 x 4 x 12V 9Ah
12h
132 x 500 x 400
41,5 kg
MODEL
1) For normal operation of the battery back-up the load connected to its output should not exceed 80% of value indicated in the table. Reserve power is essential to ensure continuous operation of 
connected devices in case of momentary rushes in load current.
2) User may modify the threshold voltage value within the range provided. Default setting is provided in parentheses.
3) After discharging the UPS with 0.8 Pmax power – charging the battery to 90% capacity.
4) Continued exposure of the battery back-up to the ambient temperature exceeding +25°C will shorten the life of batteries.
5) If the altitude above sea level increases beyond the limit provided, the permitted load power of the battery back-up decreases.
6) The acoustic signal may be turned off in the software.
sound and LED
Circuit breaker
Support time 
(100/80/50% Pmax)
Accumulator 
capacity
3)
UPS charging time 
UPS
UPS + 
battery module
UPS
Battery module
UPS
UPS + 
battery module
UPS
Battery module
UPS
Battery module
W
a
rn
in
g
T
h
e
 m
a
n
u
fa
c
tu
re
re
s
e
rv
e
s
 t
h
e
 r
ig
h
to
 c
h
a
n
g
e
 t
h
e
 a
b
o
v
e
m
e
n
ti
o
n
e
d
 p
a
ra
m
e
te
rs
 w
it
h
o
u
n
o
ti
c
e
.
Output power (apparent/active)
1)
 
Input voltage 
2)
Range of output voltage 
2)
Shape of output voltage
BACK-UP (BATTERY) OPERATION MODE
Output voltage
Shape of output voltage
Switching thresholds: UPS – mains 
2)
Filtering of output voltage
Shorting safeguard
Frequency of output voltage
Frequency of input voltage
MAINS OPERATION MODE
Switching thresholds: mains - UPS 
2)
Time to switch to UPS
Overload protection
Filtering of output voltage
Technology
Case type
Switching time: UPS – mains
ENVIRONMENTAL PARAMETERS
Software
Number and type of outlet sockets
Telephone line / LAN filter
Communication interface
Signalling
Working environment
 
Operating / storage temperature 
4
)
 
Altitude above sea level
 
5
)
Relative humidity for operation / 
storage
EQUIPMENT
Overcurrent protection
MECHANICAL PARAMETERS
Dimensions in [mm] 
(h x w x d)
Weight
Electronic
Electronic
same as input 
noise filter RFI-EMI / varistor damper
rooms with low level of pollution
20 - 80% / 20 - 95% (without condensation)
 ~150 - 170V(~160V) / ~255 - 280V (265V) ± 2% 
~165V / 260V (~155 - 175V / ~250 - 275V) ± 2%
7/8,5/19 min
4/5/9 min
5/7/15 min
28/48/81 min
25/34/65 min
17/24/46 min