CHAPTER 4: RIP 
Configuration User Manual 
76 
© Ulterius Technologies, LLC 2016. Confidential & Proprietary. 
UltOs(config-if)# exit 
4.3.3 
Configuration in FDN40-3 
Refer Figure 4-2 for Setup. 
Prerequisite: Configuration of VLAN Interfaces (vlan1 and vlan4) 
UltOs# configure terminal 
UltOs(config)# interface vlan 1 
UltOs(config-if)# shutdown 
UltOs(config-if)# ip address 10.0.0.3 255.255.0.0 
UltOs(config-if)# no shutdown 
UltOs(config-if)# exit 
UltOs(config)# vlan 1 
UltOs(config-vlan)# ports lan 0/1 untagged lan 0/1 
UltOs(config-vlan)# exit 
UltOs(config)# interface vlan 4 
UltOs(config-if)# shutdown 
UltOs(config-if)# ip address  40.2.2.2 255.255.255.0 
UltOs(config-if)# no shutdown 
UltOs(config-if)# exit 
UltOs(config)# vlan 4 
UltOs(config-vlan)# ports lan 0/4 untagged lan 0/4 
UltOs(config-vlan)# exit 
UltOs(config)# interface lan 0/4 
UltOs(config-if)# switchport pvid 4 
UltOs(config-if)# no shutdown 
UltOs(config-if)# exit 
4.4 Default Configurations 
None 
4.5 RIP Configurations 
4.5.1 
Enabling and Disabling RIP 
4.5.1.1 
Enabling RIP 
Refer the Section 4.3 for configuration guidelines and Figure 4-1 for the 
Setup. The prerequisite configuration needs to be done in the switches 
(FDN40-1 and FDN40- 2) before configuring RIP. RIP is disabled by default.