Bluetooth Special Interest Group Inc. BTSIG15A Manual De Usuario

Descargar
Página de 162
Report Generator 
103 
 
It should be noted that the set of selected test cases is not “sticky”. The set of test cases to be included in the report must 
be selected on every use of the report generator. 
Which results to choose? 
Generally, the most recent successful execution of each test case (ones with a “PASS” verdict) should be chosen for the 
report. These results indicate that the device was able to successfully execute the tests with the most recent ICS and IXIT 
settings. 
On some occasions it may be desirable to include unsuccessful results in the report. Use of the Profile Tuning Suite is 
mandated for many of the profile level test cases. An issue in a test specification, or a software problem in the PTS may 
make it impossible for a given test case to result in a “PASS” verdict. When this happens, it needs to be shown that 
execution of the test case using the PTS was attempted. Inclusion of the unsuccessful result in the report will call attention 
to the failed attempt. 
The inclusion of such results in the report can be used to help indicate that all of tests listed in the test plan created by the 
Test Plan Generator were attempted. 
8. Including test execution logs in the report 
The report created by the report generator may optionally include the detailed test execution log for each of the selected 
test cases. Inclusion of this information is not required for creating a report to be submitted as testing evidence via the 
Qualification Listing Interface.