HP rp5800 XZ958UT Manual De Usuario

Los códigos de productos
XZ958UT
Descargar
Página de 52
Weights & Dimensions
Weights & Dimensions
Weights & Dimensions
Weights & Dimensions
(configured with 1 HDD & 1 ODD)
 
Chassis
(H x W x D)
3.95 x 13.3 x 14.9 in
100 x 338 x 379 mm
System Volume
782.77 cu in
13.0 L
Tower Stand
(H x W x D)
1.1 x 7.0 x 7.9 in
29 x 178 x 200 mm
Packaging
(H x W x D)
9.0 x 19.7 x 23.4 in
229 x 500 x 594 mm
System Weight
*
15.08 lb
6.84 kg
Shipping Weight
*
16.28 lb
7.34 kg
Max Supported Weight
(desktop orientation)
77.0 lb
35.0 kg
Unit Environment and Operating Conditions
Unit Environment and Operating Conditions
Unit Environment and Operating Conditions
Unit Environment and Operating Conditions
General Unit Operating Guidelines
Keep the rp5800 Retail System away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure
that unit is operated within the specified operating range.
Leave a 10.2-cm (4-in) clearance on front side and power supply side of the rp5800 Retail System to permit the required
airflow.
If within an enclosure, the front side should be 100% open. The clearance between the system and the cabinet must be at
least 10 mm (0.4 inch) on the sides and top and at least 50-mm (2-inch) clearance in the rear with power supply venting area
100% open per the above bullet.
Never restrict airflow into the rp5800 Retail System by blocking any vents or air intakes.
Do not stack rp5800 Retail Systems on top of each other or place the rp5800 Retail Systems so near each other that they are
subject to each other's re-circulated or preheated air
Occasionally clean the air vents on the front, back, and any other vented side of the rp5800 Retail System. Lint, dust and
other foreign matter can block the vents and limit the airflow.
Temperature Range
Temperature Range
Temperature Range
Temperature Range
Operating: 50° to 104 F (10° to 40° C)
*
Non-operating: -22° to 140° F(-30° to 60° C)
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
Operating: 20% to 85% (non-condensing at ambient)
Non-operating: 5% to 90% (non-condensing at ambient)
Maximum Altitude
Maximum Altitude
Maximum Altitude
Maximum Altitude
(unpressurized)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
* Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained
sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.
NOTE:
NOTE:
NOTE:
NOTE: An optional thermal configuration is available to support 50C ambient temperatures. This is a factory configurable
configuration only.
 
QuickSpecs
HP rp5800 Point of Sale System
HP rp5800 Point of Sale System
HP rp5800 Point of Sale System
HP rp5800 Point of Sale System
Technical Specifications
DA - 13982   North America — Version 4 — May 27, 2011