Advanced Warning Systems LLC AWS-RC Manual De Usuario
INSYTE PRODUCT OPERATION DESCRIPTIONS
Page 4 of 8
b) Chirp sound indicates ready condition and battery health
c) 30 second delay timer for placement/storage prior to arming/activation
d) Press switch down momentarily for power off (within 3 seconds of handling)
Once the system has been powered on and in armed status, the warning circuit will be activated only when the unit is
moved or disturbed, utilizing an Omni-directional Motion Sensor, which sends a signal to the Microchip controller, that
is programmed to drive a Piezoelectric Transducer, producing a minimum of 85db @ 3.5kHz warning sound for a
duration of 5 - 10 seconds, then will reset. A second and more urgent (sweep or pulsed sound) is produced if the
Magnetic Reed Switch has been activated by the removal of the Slide Lock Assembly. To turn off the system, you must
depress the momentary switch within 2-3 sec. after disturbing the unit.
PART II: Remote Control
The Remote Control for the InSyte devices provides a convenient way to operate the InSyte devices,
especially with multiple units of InSyte devices. One remote control can manage up to 30 InSyte devices
(including InSyte devices and Stealth Cameras). We use four numeric keys in remote control, the same as
on InSyte device.
There are 12 keys on the keypad for user input: one Power key “ ”, four arrow keys “
”, and one
Enter key “ ”, six command control keys which we name them as “ ”, “ ”, “ ”, “ ”, “ ”, and “ ”.
For easier document writing, we use the following symbols “
” for the keys respectively.
THREE more keys: “ ”[MENU], “ ”[OPTION] and “ ”[DELETE]. The meaning of each key is
defines as follows:
“ ”: Command Button: This key is used to initiate a command sequence. This button is the same as the “ ”
button on the InSyte keypad.
“ ”, “ ”, “ ”, and “ ”: Numeric keys: These keys are used to instruct the actions defined be the key
sequence combinations. The following document will explain them in details.
“ ”: Control Button: This is another special button (we also call it the “confirm button”). This key is used to
end a command sequence or to confirm user key input action. This button is the same as the “ ” button on the
InSyte keypad.
“ ”, “ ”, “ ”, and “ ”: Arrow keys: These keys are used to move the selection cursor in four directions.
“ ”: Enter Button (OK butrton): This key is used to accept the cursor selection and to perform the selected
command action.
“ ”: Menu Button: This key is access the Command Menu system, which will allow user to use the cursor
selection and to perform the selected menu command action.
“ ”: Option Button: This key is access the Option Menu which will allow user to use the cursor selection and
to perform the selected option menu action.
“ ”: Delete Button: This key is used to correct error when user enters wrong numeric digit.
Main Functions of the Remote Control:
Turn ON the Remote Control
Link an InSyte device or Stealth Camera to Remote Control
Execute a command
Select an option
Turn on the Remote Control device:
When the RC device is turned on, a Welcome screen will be displayed at first, maybe with date, status, and other
information displayed on the OLED screen.