Setting the Repeat Interval for Cancel Mode:
The repeat interval is the setting that tells the system how often to repeat a page to the staff in Cancel
mode. For example: if you set this setting to 30 seconds, the system will repeat the page to the staff
member every 30 seconds until the staff members page has been cleared. This is also the case for Notify
Manager mode.
mode. For example: if you set this setting to 30 seconds, the system will repeat the page to the staff
member every 30 seconds until the staff members page has been cleared. This is also the case for Notify
Manager mode.
1.
Press the FUNC button 8 times. This should then show
the current setting of the Repeat Interval.
2.
Press the X3 button once.
3.
Entered the desired time in seconds using the numbered
keys. Use the 10 key to enter 0.
4.
Press the X3 key to save.
5.
Press the X2 key to exit the settings screens.
Setting the Notify Manager Timing for Notify Manager Mode
Notify manager Mode is useful to notify managers that the kitchen may be waiting too long for wait
staff to pick up orders from the kitchen. The Notify Manager Timing setting lets you set how long before
the system alerts a manager that an order has not been picked up.
staff to pick up orders from the kitchen. The Notify Manager Timing setting lets you set how long before
the system alerts a manager that an order has not been picked up.
**It is VERY important that this setting is not lower than the Repeat Interval for Cancel Mode as set
previously. If it is set too low, it can cause a paging loop and produce undesired operation. Please set it
to be a minimum of 2 times the value of your Repeat Interval**
previously. If it is set too low, it can cause a paging loop and produce undesired operation. Please set it
to be a minimum of 2 times the value of your Repeat Interval**
1.
Press the FUNC button 5 times. This should then show
the current setting of the Notify Manager Time.
2.
Press the X3 button once.
3.
Entered the desired time in seconds using the numbered
keys. Use the 10 key to enter 0.
4.
Press the X3 button to save.
5.
Press the X2 button to exit the setting screens.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
1) this device may not cause harmful interference, and 2) this device must accept any interference
received, including interference that may cause undesired operation.
1) this device may not cause harmful interference, and 2) this device must accept any interference
received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against