SID Global Sdn Bhd UR-001 Manual De Usuario
1-Port and 4-Port UHF RFID Reader User Manual
UHF RFID User Manual
20
When the choose completes, click on Select and the following screen displays:
We could see that the checkbox on the left for Selected Tag has been selected, the
Selected EPC NO. displays in the text box on the left.
Next, all the operations are only for the tag with this EPC NO.
If you want to cancel the match of EPC, just deselect the checkbox for Selected Tag,
as below:
2.4.6 Error Display Might Be Returned
There will be some warning of error if we did wrong operations in the process of
accessing tags.
ƹInventory Success, access failure:
Actually there are two-steps to access tag: first inventory tag, second access tag.
Prompt in the above image means inventory tag successfully, but can’t access.
Generally, there are two reasons lead to this problem. One is the parameter settings
are incorrect, for example, read a storage area not exist. The other reason is RF
energy is not enough, distance of access tab is about 60%-70% distance of inventory
tag, so please move the tag closer to the antenna.