                            YRU-150 User Manuel installation and operations guide Ver.0.2 
  版權所有,翻版必究
 
  Engineering model 
 
1. Select Reader Setting and press Set bottom to enter engineering model 
 
2. Frequency calibration 
2.1 Select test Region《1》. 
2.2 Select test frequency《2》and press Set to completed. 
2.3 Key in the measurement value by Spectrum Analyzer《3》and press Adjust to completed. 
2.4 Adjust manually《4》, press 
“+” & “-” bottom to calibration. 
3. Power setting 
Select power value《5》  and press Set to completed. 
4. Carry measurement 
4.1 S
elect “Carry” and chose frequency《6》, press Set bottom to running test. 
4.2 Select “Rx” and chose frequency《6》, press Set bottom to running test. 
5. Modulation testing 
Press “Run” to test modulation test.