Duration 
Surge 
Operating AC Voltage  Line Frequency 
Performance Criteria 
Continuous 
10% 
Nominal AC Voltage 
50/60 Hz 
No loss of function or performance 
0 - ½ AC cycle 
30% 
Mid-point of Nominal AC 
Voltage  
50/60 Hz 
No loss of function or performance 
 
3. DC Output Specification 
!
3.1  Output Power / Currents 
Table 4: Load Range 
Voltage 
Minimum Load 
Maximum Load 
+3.3V 0.1A  28A 
+5V 0.1A 32A 
+12V 0.5A  41A 
-12V  
0A 
0.5A 
+5VSB  
0.1 
3A 
!
Notes: 
1: The +3.3 &+5 Volt total outputs shall not exceed 200W. 
 
3.2  Voltage Regulation, Ripple and Noise 
Table 5:    Regulation, ripple and noise 
Output Voltage 
+3.3V 
+5V 
+12V 
-12V(Optional) +5VSB(Optional)
Load Reg. 
±5% 
±5% 
±5% 
±10% 
±5% 
Line Reg. 
±1% 
±1% 
±1% 
±1% 
±1% 
Ripple & Noise   
60mV 
60mV 
120mV 
120mV 
60mV 
 
Ripple and noise shall be measured using the following methods: 
a) Measurements made differentially to eliminate common-mode noise 
b) Ground lead length of oscilloscope probe shall be 
≤ 0.25 inch. 
c) Measurements made where the cable connectors attach to the load. 
d) Outputs bypassed at the point of measurement with a parallel combination of 
10uF tantalum capacitor in parallel with 0.1uF ceramic capacitors. 
e) Oscilloscope bandwidth of 0 Hz to 20MHz. 
f) Measurements measured at locations where remote sense wires are connected. 
g) Regulation tolerance shall include temperature change, warm up drift and dynamic load 
 
3.3 Capacitive 
Loading 
The power supply shall be stable and meet all requirements in the following table, except dynamic loading 
requirements.