Cisco MCS 7816-I5 MCS7816I5-K9-CMD3A Hoja De Datos

Los códigos de productos
MCS7816I5-K9-CMD3A
Descargar
Página de 5
 
 
Data Sheet 
© 2010 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 3 of 5 
Component 
Value 
Leakage current (mA) 
0.47 (idle; maximum measured; system rated) 
Power (watts) 
68 (idle) 
174 (maximum measured) 
351 (system rated) 
VA rating (VA) 
70 (idle) 
178 (maximum measured) 
351 (system rated) 
BTU rating (BTU/hr) 
232 (idle) 
594 (maximum measured) 
2047 (system rated) 
Rated line voltage: 200-240 VAC; 50 or 60 Hz 
Input current (amps) 
0.33 (idle) 
0.82 (maximum measured) 
3.0 (system rated) 
40 (peak inrush current; 4 ms) 
Leakage current (mA) 
0.47 (idle; maximum measured; system rated) 
Power (watts) 
67 (idle) 
171 (maximum measured) 
351 (system rated) 
VA rating (VA) 
68 (idle) 
175 (maximum Measured) 
351 (system rated) 
BTU rating (BTU/hr) 
229 (Idle) 
583 (maximum Measured) 
2047 (system rated) 
Power supply output power 
Rated steady-state power 
351W 
Operating 
50 to 95°F (10 to 35°C) 
at 0-3000 ft (0-914.4m) 
with an altitude de-rating of 
1.4°F (0.75°C) per 1000 ft (304.8m)  
Nonoperating 
50 to 109.4°F (10 to 43°C) 
Temperature range 
Shipment 
-104 to 140°F (-40 to 60°C) 
Relative humidity (RH; 
noncondensing) 
Operating 
Shipment 
8 to 80% 
8 to 80% 
Maximum altitude 
7000 ft 
2133m 
Acoustic noise 
Operating minimum  
L WAd (bels) 6.5 
Airflow (cubic feet per minute 
[cfm]) 
20 cfm minimum 
31 cfm maximum 
Remote management 
IBM Integrated Management Module included (user-installable Virtual Media Key available) on a shared Ethernet 
connector 
*
 Maximum measured values were determined with 77°F  (25°C) ambient temperature, and your results may va ry. 
*
 Idle power: Power drawn with the machine(s) logged into the OS, and no other applications running. Memory, HDDs, optical 
drives, and tape drives are not being used. 
*
 Measured maximum power: Maximum measured power is the power drawn by the machine with the CPUs 100-percent used and 
memory is used 10 percent more than base usage. The exerciser used is Prime95 (torture test). You can download it at 
*
 Rated system maximum: The maximum power the machine can draw according to the system label rating. 
Table 2. 
Equipment Approvals and Safety 
Equipment Approvals and Safety