HP 380p Gen8 670853-S01 Manual De Usuario

Los códigos de productos
670853-S01
Descargar
Página de 57
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
Maximum Peak Power
For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
For 750 W Power Supply:
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
For 460 W Power Supply:
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Altitude
Altitude
Altitude
Altitude
Operating
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109). The listed sound levels apply to
standard shipping configurations. Additional options may result in increased
sound levels.
NOTE:
NOTE:
NOTE:
NOTE: The Listed sound levels apply to standard shipping configurations.
Additional options may result in increased sound levels.
0
0
0
0
Entry
Entry
Entry
Entry
Base
Base
Base
Base
Performance
Performance
Performance
Performance
Idle
Idle
Idle
Idle
 
 
 
 
 
 
 
 
 
 
 
 
LWAd
4.1 B
4.1 B
4.1 B
LpAm
25 dBA
25 dBA
25 dBA
QuickSpecs
HP ProLiant DL380p Generation8 (Gen8)
HP ProLiant DL380p Generation8 (Gen8)
HP ProLiant DL380p Generation8 (Gen8)
HP ProLiant DL380p Generation8 (Gen8)
Technical Specifications
DA - 14212   North America — Version 9 — April 12, 2012