Specifications
Pulsar MX 4000 RT 
Pulsar MX 5000 RT 
Pulsar MX 15000 Frame 16U
Pulsar MX 20000 Frame 16U
Pulsar MX RT Tower or rack-mounting: standard backup time
68 501
68 504
68 513
(14)
68 514
(15)
Pulsar MX RT Netpack: standard backup time 
68 502
68 505
(with rack kit, 
(with rack kit, 
+ NMC + rack kit
casters, NMC card) 
casters, NMC card)  
Pulsar MX EXB RT : battery extension module
68 515
68 527 (Pulsar MX Frame EXB empty to be fitted with 4 or 8 Battery sub-modules) 
Pulsar MX ModularEasy: paralleling kit (2 Pulsar MX) 
68 520
-
MX / EXB RT Rack Kit: rail kit for 19" rack mounting 
68 002
-
IEC 32 A kit , 2 X 2 m long cables: male to 
68 525
-
hardwired and female to hardwired 
Pulsar MX Battery / Power electronics sub-module 
68 524 / 68 522 
68 524 / 68 523 
68 524 / 68 523 
Part numbers 
1: Available from November 2006. 2: 2 Pulsar MXs can be paralleled using ModularEasy. 3: At 70% load. 4: 4 IEC C13 (10A) 2 m long cables for use with retention clips (8 cables for use with Pulsar MX Frame).
5: Frequency conversion for non-paralleled units only. 6: Economy mode, 91% in normal mode. 7: At 70% nominal rating with power factor 0.7 typical values after 3 charge/discharge cycles, with 3-5 year old
batteries. Weekly battery test without interrupting the load (daily or monthly if required). EXB compatible with 0.8 power factor loads. 8: With Pulsar MX Frame EXB (4 battery units). 9: With Pulsar MX Frame EXB
(8 battery units). 10: Solution-Pac CD-ROM supplied as standard. 11: Applicable to US models. 12: 50 dbA above 5 kVA. 13: Depending on the country, see www.mgeups.com/service. 14: 68 513 = 68 526
(empty Pulsar MX Frame) + 3 x 68 524 + 3 x 68 523. 15: 68 514 = 68 526 (empty Pulsar MX Frame) + 4 x 68 524 + 4 x 68 523.
Pulsar MX RT
4 kVA 
5 kVA 
15 kVA
(1)
20 kVA
(1)
Rating (kVA) / (kW) 
4 kVA / 3,6 kW
5 kVA / 4,5 kW
15 kVA / 13, 5 kW
20 kVA / 18 kW
Paralleling 
Maximum rating / 
8 kVA / 4 kVA + 4 kVA redundancy
10 kVA / 5 kVA + 5 kVA redundancy 15 kVA / 10 kVA + 5 kVA redundancy 20 kVA / 15 kVA + 5 kVA redundancy
redundancy
(2)
5 kVA + 2 x 5 kVA redundancy
10 kVA + 2 x 5 kVA redundancy 
Inputs 
Technology
VFI-SS-113, on-line double conversion with power factor correction, convection cooled static bypass switch 
Number of phases, input connections 
L + N, terminals up to 6 mm
L + N or 3P + N, terminals up to 35 mm
2
,
separate or common AC normal and AC bypass
Nominal voltage 
200/208/220/230/240/250 V
200/208/220/230/240/250 V (L + N) or 380/400/415 V (3P + N) 
Voltage range without using battery
(3)
120 - 280 V 
120 - 280 V (L + N), 250 - 465 V (3P + N) 
Input frequency range, THDI 
40-70 Hz, < 7%
Outputs 
Output connections
(4)
terminals + 8 IEC C13 (10A) + 2 IEC C19 (16A) 
terminals + 16 IEC C13 (10A) + 4 IEC C19 (16A) 
Remotely controlled Powershare sockets 
2 groups (2 IEC C13 10A per group) 
2 groups (4 IEC C13 10A per group) 
Output voltage and frequency
(5)
, THDU, efficiency
(6)
200/208/230/240 /250 V, 50 / 60 Hz autoselect, frequency converter as standard, <2%, 97% 
Backup time
(7)
Pulsar MX standard backup time 
10 minutes
8 minutes 
8 minutes 
Pulsar MX + EXB / MX + 2 EXB / MX + 3 EXB
45 / 80 / 120 minutes
35 / 60 / 95 minutes
20 minutes
(8)
/ 35 minutes
(9)
Communications 
Slots 
1 minislot or 2 minislots (Frame) compatible with Minislot NMC, NMC ModBus/JBus, MC Contacts/Serial 
Ports
Remote Power off (RJ11), 5 output contacts (DB9), setup using Solution-Pac
(10)
(USB and DB9-serial ports), 
EXB module detection (RJ45), paralleling (DB 15)
Operating conditions, standards and approvals 
Performance, safety, EMC, surge protection 
IEC/EN 62 040-3, IEC/EN 62 040-1-1, IEC/EN 62 040-2 class A (class B as option), 4 kV IEC 61 643, UL 1778 and CSA 22.2
(11) 
Operating temperature, noise, approvals, guarantee 
0°C to 40°C continuous, 45 dbA
(12)
, UL, TüV, GS mark, CB, C-Tick, CE, IEC 61 931, one year
(13)
Dimensions / weight 
Pulsar MX RT standard backup tower 
444.5 mm high x 130.6 mm wide x 735 mm deep / 57 kg 
Tower 690 mm high (795 mm casters) x 444.5 mm wide x 735 mm deep /  
Pulsar MX RT standard backup rack 
3U x 444.5 mm wide compatible with 800-1000 mm deep rack 
250 kg Rack 16U x 444.5 mm wide, compatible with 800-1000 mm deep rack 
MX EXB battery unit tower / rack 
444.5 mm high x 130.6 mm wide x 650 mm deep / 3U x 444.5 mm wide / 70 kg
dimensions same as MX Frame / 230 kg for 15 kVA, 290 kg for 20 kVA 
Pulsar MX ModularEasy, paralleling kit 
dimensions same as EXB battery unit / 10 kg 
-
Communications
Solution Pac 2 suite supplied for remote
supervision.
MGE's Enterprise Power Manager for supervision
via Ethernet and Teleservice. EPM is compatible
with standard network management systems
(Tivoli, CA unicenter, HP Openview).
Compatible with Network Shutdown Module 
for monitoring a number of UPSs and shutting
down the servers on the network.
MGE PowerServices™
1 year guarantee, including batteries.
Associated services 
(1)
Extended guarantee.
Commissioning.
Teleservice (in-band and out-of-band).
Personalised maintenance contracts.
1: Depending on the country, see www.mgeups.com/services.
2 IEC 16A outlet sockets
Output circuit protection
1 minislot for NMC, Modbus/JBus 
or MC Contacts/Serial card
RJ11 remote power off
RJ45 EXB battery module detection
DB9 with 5 output contacts 
EXB battery extension module power connector
DB 15 paralleling
DB 9 serial and USB ports:
Setup and supervision
Input 
Output
8 IEC 10A outlet sockets
Retention clips