Polycom 2215-28454-001 Manual De Usuario

Descargar
Página de 27
Deployment Guide for Maximum Security Environments
Polycom, Inc. 
11
You can configure the period of time, in hours, in which the failed login 
threshold must be exceeded to lock the user’s account. This command can only 
be changed through the command-line interface using the serial API:
loginwindowduration: Set to 1, range is 1 to 24. Off is not allowed.
External Authentication
Home Screen and Other Settings
Lock Port after Failed Logins
Set to 3, configurable. Off is not allowed.
Port Lock Duration in Minutes 
Set to 1, configurable. Off is not allowed.
Setting
Restriction
Setting
Restriction
Enable Active Directory 
Authentication
Enabled, configurable.
Setting
Restriction
Idle Session Timeout in Minutes
Set to 10, configurable. Off is not allowed.
Lock Port after Failed Logins
Set to 3, configurable. Off is not allowed.
Port Lock Duration in Minutes 
Set to 1, configurable. Off is not allowed.
Setting
Restriction
Serial Ports: RS-232 Mode
Set to Off, configurable (only Control is 
allowed).
SIP Transport Protocol
SIP not available.
Directory Servers
Only LDAP available.
Auto Answer Point-to-Point Video
Disabled, configurable.
Auto Answer Multipoint Video
Disabled, configurable.
Availability Control
Enabled, not configurable.
Recent Calls
Disabled, not configurable.
Last Number Dialed
Disabled, not configurable.
Far Control of Near Camera
Disabled, configurable.