Polycom 2215-28454-001 Manual De Usuario

Descargar
Página de 27
Deployment Guide for Maximum Security Environments
Polycom, Inc. 
7
Configuring Security Settings in a Web Browser
You can configure some of the security settings on the local HDX system 
screens. For other security settings, however, you must use the HDX system 
web interface.
Using the Maximum Security Profile
The Maximum Security Profile lets you control particular fields to meet the 
highest security requirements (for example, systems used in government or 
military environments). The Security Profile can be set only in the setup 
wizard. You can run the setup wizard:
• At initial setup
• When you select Erase System Flash Memory during a system update
• After a system reset when system settings are deleted
After the setup wizard is complete, the Security Profile setting appears as 
read-only in the Admin Settings.
To set the Security Profile to Maximum:
>>
In the setup wizard, enable Security Mode and set Security Profile to 
Maximum
When you choose this setting, the system automatically sets certain fields to 
predefined values. After you set the Security Profile to Maximum in the setup 
wizard, some fields are restricted or not configurable. The fields controlled by 
the profile are set to predefined values and might have additional restrictions 
applied as described in the following tables.
Setup Wizard
Setting
Restriction
Admin ID
Must be changed.
User ID
Must be changed.
User Room Password
Must be entered.
User Remote Password
Must be entered.
Admin Room Password
Must be changed.
Admin Remote Password
Must be changed.