Power Sub-system
Intel
®
Entry Server Chassis SC5299-E TPS
Revision
3.1
Intel order number D37594-005
14
Table 7. P10 Right-angle SATA Power Connector
Pin
Signal
24 AWG Color
1 +3.3V
Orange
2 Ground
Black
3 +5V
Red
4 Ground
Black
5 +12V2
Blue/White
2.1.4
AC Input Requirements
The power supply operates within all specified limits over the following input voltage range,
shown in the following table. Harmonic distortion of up to 10% THD must not cause the power
supply to go out of specified limits. The power supply does power off if the AC input is less than
75VAC +/-5VAC range. The power supply starts up if the AC input is greater than 85VAC +/-
4VAC. Application of an input voltage below 85VAC does not cause damage to the power
supply, including a fuse blow.
shown in the following table. Harmonic distortion of up to 10% THD must not cause the power
supply to go out of specified limits. The power supply does power off if the AC input is less than
75VAC +/-5VAC range. The power supply starts up if the AC input is greater than 85VAC +/-
4VAC. Application of an input voltage below 85VAC does not cause damage to the power
supply, including a fuse blow.
Table 8. AC Input Rating
PARAMETER
MIN
Rated
MAX
Max Input
Current
Start up VAC
Power Off VAC
Voltage (110)
90 V
rms
100-127
V
rms
135
V
rms
7.7
A
rms
85Vac
+/-
4Vac
75Vac +/-
5Vac
5Vac
Voltage (220)
180 V
rms
200-240
V
rms
265
V
rms
4.3
A
rms
Frequency
47 Hz
63 Hz
2.1.4.1
AC Inlet Connector
The AC input connector is an IEC 320 C-14 power inlet. This inlet is rated for 15A/250VAC.
2.1.4.2
Efficiency
The power supply has an efficiency of 68.5% at maximum load and over the specified AC
voltage.
voltage.
2.1.4.3
AC Line Dropout/Holdup
An AC line dropout is defined to be when the AC input drops to 0VAC at any phase of the AC
line for any length of time. During an AC dropout of one cycle or less the power supply meets
dynamic voltage regulation requirements over the rated load. An AC line dropout of one cycle or
line for any length of time. During an AC dropout of one cycle or less the power supply meets
dynamic voltage regulation requirements over the rated load. An AC line dropout of one cycle or