Bunn JDF-4SB Manual De Usuario

Descargar
Página de 57
15
SERVICE (CONT.)
Ballast (JDF-2S,4S)
P1684.40
FIG. 3 BALLAST
Location:
The door lamp ballast is located inside the dispenser 
door mounted in the center of the door rear cover.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Disconnect a black and blue wire from one set of 
lamp sockets.
3.  Connect an ohmmeter to the end of each wire.
4.  Check for continuity between the two wires.
If continuity is present as described, the ballast is 
operating properly.
If continuity is not present as described, replace the 
ballast.
5.  Check for continuity between the other pair of black 
and blue wires.
Removal and Replacement:
1.  Disconnect the dispenser from the power source.
2.  Remove door cover by taking out the 5 screws and 
unplug the dispense switch harness from the door 
harness. Set door cover and screws aside.
3.  Disconnect the 3-pin connector from the ballasts 
to the door harness.
4.  Remove fluorescent bulbs from the brackets. Pull 
off the four snap-in light sockets from the light 
panel.  
FIG. 4 BALLAST TERMINALS
P1219
5.  Remove the wire to the ballast from the back of 
each bracket. 
6.  To disengage the ballast wire from the bracket, push 
a 1/16” allen wrench (or equivalent tool) into the 
front hole that lines up with the wire in the back.   
Pull the wire out.  
7.  Repeat for each bracket.
8.  White jumper must remain in place on the back of 
the light socket.
9.  Remove screws from each ballast. Remove the green 
ground wire from the ballast bracket by removing 
the bracket’s bottom screw.
10. Install the single ballast (wires on the bottom) onto 
the ballast bracket using 2 of the screws previously 
removed.
11. Attach ballast wires to the back of bulb sockets by 
pushing wires into holes in back of socket.
Note: Attach black wires to the top sockets, and blue 
wires to the bottom sockets. Reference electrical sche-
matic if needed.
12. Snap all 4 bulb sockets back onto light panel. Re-
install fluorescent bulbs.
13. Attach green ground wire to the bottom hole of the 
ballast bracket using 1 screw.
14. Plug in 3-pin connector into the door harness.
15. To replace door cover, re-connect the dispense 
switch harness to door harness. Fasten with 5 
screws. 
16. Reconnect power to the unit. Test operation.
JDF-2S shown
49179  110613