Bunn JDF-4SB Manual De Usuario

Descargar
Página de 57
48
+
A
A
SERVICE (CONT.)
Transformer (all Models)
Removal and Replacement:
1.  Loosen the two #8-32 screws securing the com-
ponent bracket to the dispenser housing base.
2.  Pull component bracket out the front of the dispenser 
far enough so the transformer can be disconnected 
from the main wiring harness.
3  Remove the two #6-32 keps nuts securing the 
transformer to the component bracket.
5.  Remove and discard the transformer.
6.  Install new transformer on the component bracket 
and secure with two #6-32 keps nuts.
7.  Refer to Fig. 70 and connect the transformer to the 
main wiring harness.
8.  Place the component bracket into position and 
tighten the two #8-32 screws.
BLU  to Control 
Board J6-3,J12-3
WHI/BLU to Control 
Board J6-1,J12-1
WHI from
Power Cord
BLK from
Power Cord
FIG. 70  TRANSFORMER TERMINALS
P1647
FIG. 69 TRANSFORMER
Location:
  The transformer is located on the electrical com-
ponent mounting bracket on the lower front of the 
dispenser behind the splash panel.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Check the voltage across black wire and the white 
wire from the main harness. Connect the dispenser 
to power source. The indication must be:
 
a) 120 volts ac for two wire 120 volt models, three 
wire 120/208 volt and three wire 120/240 volt 
models.
 
b) 240 volts ac for two wire 240 volt models.
 
c) 230 volts ac for two wire 230 volt models.
4.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the Wiring 
Diagrams and check the main wiring harness.
5.  Check the voltage between J6-1 and J6-3 at the 
control board. Connect the dispenser to the power 
source. The indication must be 24 volts ac.
If voltage is present as described the transformer is 
operating properly.
If voltage is not present as described, replace the 
transformer.
P3864
49179  110613