SECTION 7: SERVICE
Troubleshooting
Motor & Electrical
Symptom
Possible Cause
Possible Solution
Machine  does 
not  start  or  a 
breaker trips.
1.  Plug/receptacle is at fault or wired incorrectly.
2.  Motor connection wired incorrectly.
3.  Power supply is at fault/switched OFF.
4.  Motor ON/OFF switch is at fault.
5.  Centrifugal switch is at fault.
6.  Wiring is open/has high resistance.
7.  Start capacitor is at fault.
8.  Motor is at fault.
1.  Test for good contact or correct the wiring.
2.  Correct motor wiring connections (
Page 54).
3.  Ensure hot lines have correct voltage on all legs and 
main power supply is switched ON.
4.  Replace faulty ON/OFF switch.
5.  Adjust/replace the centrifugal switch if available.
6.  Check for broken wires or corroded/disconnected con-
nections, and repair/replace as necessary.
7.  Test/replace if faulty.
8.  Repair/replace.
Machine  stalls 
or is underpow-
ered.
1.  Wrong workpiece material (wood).
2.  Processing speed too fast for task.
3.  V-belt slipping.
4.  Blade is slipping on wheels.
5.  Low power supply voltage.
6.  Run capacitor is at fault.
7.  Plug/receptacle is at fault.
8.  Motor connection is wired incorrectly.
9.  Motor bearings are at fault.
10. Motor has overheated.
11. Motor is at fault.
12. Centrifugal switch is at fault.
1.  Use wood with correct moisture content, without glues, 
and little pitch/resins.
2.  Decrease processing speed.  See 
Basic Cutting Tips 
on 
Page 32.
3.  Replace  bad  V-belt,  align  pulleys,  and  re-tension 
(
Page 49).
4.  Adjust blade tracking and tension to factory specifica-
tions. See 
Page 22 or 27.
5.  Ensure all hot lines have correct voltage on all legs.
6.  Repair/replace.
7.  Test for good contacts and correct wiring.
8.  Correct motor wiring connections (
Page 54).
9.  Test  by  rotating  shaft;  rotational  grinding/loose  shaft 
requires bearing replacement.
10. Clean off motor, let cool, and reduce workload.
11. Repair/replace.
12. Adjust/replace centrifugal switch if available.
Disconnect power to the 
machine  when  perform-
ing  any  troubleshooting. 
Failure  to  do  this  may 
result in serious person-
al injury.