System Status LED
Table 50. System Status LED Operation
Color
State
Criticality
Description
Off
N/A
Not ready
Power off or BMC initialization completes if no degraded, non-
critical, critical, or non-recoverable conditions exist after power cable
plug in
critical, critical, or non-recoverable conditions exist after power cable
plug in
Green/
Amber
Amber
Both Solid
On
On
Not ready
Pre DC Power On – 15-20 second BMC Initialization when AC is
applied to the server. The system will not POST until BMC
initialization completes.
applied to the server. The system will not POST until BMC
initialization completes.
Green
Solid on
Ok
System ready
Green Blink
Degraded
BIOS detected
1. Unable to use all of the installed memory (more than one DIMM
1. Unable to use all of the installed memory (more than one DIMM
installed).
1
2. In a mirrored configuration, when memory mirroring takes place
and system loses memory redundancy. This is not covered by
(2).
(2).
1
3. PCI Express* correctable link errors.
Integrated BMC detected
1. One of redundant power supplies not present.
2. CPU disabled – if there are two CPUs and one CPU is disabled.
3. Fan alarm – Fan failure. Number of operational fans should be
Integrated BMC detected
1. One of redundant power supplies not present.
2. CPU disabled – if there are two CPUs and one CPU is disabled.
3. Fan alarm – Fan failure. Number of operational fans should be
more than minimum number needed to cool the system.
4. Non-critical threshold crossed – Temperature, voltage, power
nozzle, power gauge, and PROCHOT2 (Therm Ctrl) sensors.
5. Battery
failure.
6. Predictive failure when the system has redundant power
supplies.
Amber
Blink
Non-critical
Non-fatal alarm – system is likely to fail
BIOS Detected
1. In non-mirroring mode, if the threshold of ten correctable errors
BIOS Detected
1. In non-mirroring mode, if the threshold of ten correctable errors
is crossed within the window.
1
2. PCI Express* uncorrectable link errors.
Integrated BMC Detected
1. Critical threshold crossed – Voltage, temperature, power nozzle,
Integrated BMC Detected
1. Critical threshold crossed – Voltage, temperature, power nozzle,
power gauge, and PROCHOT (Therm Ctrl) sensors.
2. VRD Hot asserted.
3. One of the redundant power supplies failed.
4. Minimum number of fans to cool the system are not present or
3. One of the redundant power supplies failed.
4. Minimum number of fans to cool the system are not present or
have failed.
Amber
Solid on
Critical, non-
recoverable
recoverable
Fatal alarm – system has failed or shutdown
BIOS Detected
1. DIMM failure when there is one DIMM present and no good
BIOS Detected
1. DIMM failure when there is one DIMM present and no good
memory is present.
1
2. Run-time memory uncorrectable error in non-redundant mode.
1
3. CPU configuration error (for instance, processor stepping
mismatch).
Integrated BMC Detected
1. CPU CATERR signal asserted.
2. CPU 1 is missing.
1. CPU CATERR signal asserted.