HP ProLiant DL385 G2 AMD Opteron 2210 HE Dual Core Processor 2MB 1GB 1P Entry Model Rack Server 434940-421 Manual De Usuario
Los códigos de productos
434940-421
External Storage
External Storage
External Storage
External Storage
Quantity
Quantity
Quantity
Quantity
Supported
Supported
Supported
Supported
Position
Position
Position
Position
Supported
Supported
Supported
Supported
Host Controller or Adapter
Host Controller or Adapter
Host Controller or Adapter
Host Controller or Adapter
Modular Smart Array 50
Enclosure
Enclosure
2 per connector
(supports 1+1
cascading)
External
HP Smart Array P600/256 BBWC Controller
NOTE:
NOTE:
NOTE:
NOTE: Optional mixed PCI-X/E cage required.
Modular Smart Array 500
G2
G2
1 per SCSI
External
Please see the Modular Smart Array 500 or 500 G2 QuickSpecs
for the latest list of supported HBAs:
for the latest list of supported HBAs:
Maximum Storage Capacity
Maximum Storage Capacity
Maximum Storage Capacity
Maximum Storage Capacity - (SAS with MSA50)
Internal
1.168TB (8 x 146 GB SAS SFF)
External
2.920TB (20 x 146 GB SAS SFF)
Total
4.088TB
Tape and Disk-Based Backup
Tape and Disk-Based Backup
Tape and Disk-Based Backup
Tape and Disk-Based Backup
NOTE:
NOTE:
NOTE:
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the following:
NOTE:
NOTE:
NOTE:
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Autoloaders and Tape Libraries listed below,
please see the following:
please see the following:
(Worldwide)
NOTE:
NOTE:
NOTE:
NOTE: For complete listing of tape drive offerings see:
NOTE:
NOTE:
NOTE:
NOTE: SAS Tape Drives: Connecting hard drive cage and SAS tape to the same SAS Controller using split cable (supplied with tape
drive) deactivates 1 of the hard drive bays. Actual hard drive bay deactivated depends on where split cable plugs into SAS drive
connector. Example: 3x SAS cable connector plugged into SAS drive connector (5-8) on the back of the hard drive cage would
mean drive bay 8 is deactivated.
drive) deactivates 1 of the hard drive bays. Actual hard drive bay deactivated depends on where split cable plugs into SAS drive
connector. Example: 3x SAS cable connector plugged into SAS drive connector (5-8) on the back of the hard drive cage would
mean drive bay 8 is deactivated.
Position
Position
Position
Position
Supported
Supported
Supported
Supported
Controller
Controller
Controller
Controller
Controller Part
Controller Part
Controller Part
Controller Part
Number
Number
Number
Number
HP StorageWorks SCSI
HP StorageWorks SCSI
HP StorageWorks SCSI
HP StorageWorks SCSI
Tape Drives, External
Tape Drives, External
Tape Drives, External
Tape Drives, External
Tape Drives, External
LTO-1 Ultrium 232
LTO-2 Ultrium 448
LTO-3 Ultrium 960
LTO-3 Ultrium 920
LTO-4 Ultrium 1760
LTO-4 Ultrium 1840
DAT 40
DAT 72
DAT 160
1U Rack-Mount Kit
3U Rack-Mount Kit
LTO-1 Ultrium 232
LTO-2 Ultrium 448
LTO-3 Ultrium 960
LTO-3 Ultrium 920
LTO-4 Ultrium 1760
LTO-4 Ultrium 1840
DAT 40
DAT 72
DAT 160
1U Rack-Mount Kit
3U Rack-Mount Kit
External
HP SC11Xe Host Bus Adapter
412911-B21
QuickSpecs
HP ProLiant DL385 Generation 2 (G2)
HP ProLiant DL385 Generation 2 (G2)
HP ProLiant DL385 Generation 2 (G2)
HP ProLiant DL385 Generation 2 (G2)
Storage
DA - 12565 Worldwide — Version 41 — July 23, 2008
Page 39