HP DL560 G8 686785-001 Manual De Usuario

Los códigos de productos
686785-001
Descargar
Página de 48
System Unit
Dimensions (H x W x
D)
(with bezel)
SFF Drives: 3.44 x 17.54 x 29.50 in (8.73 x 44.55 x 74.93 cm)
Weight
(approximate)
Maximum
(all SFF hard drives,
power supply, and
processor installed)
61.00 lb (27.66 kg)
Input Requirements
(per power supply)
Rated Line Voltage
100 to 120 VAC
200 to 240 VAC
Rated Input Current
For 1200 W Power Supply:
10 A (at 100 VAC),
4.9 A (at 200 VAC)
Rated Input Frequency 50 to 60 Hz
Rated Input Power
For 1200 W Power Supply:
930 W (at 100 VAC),
1348 W (at 200 VAC)
BTU Rating
Maximum
For 1200 W Power Supply:
3530 BTU/hr (at 100 VAC),
4600 BTU/hr (at 200 VAC)
Power Supply Output
(per power supply)
Rated Steady-State
Power
For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
Maximum Peak Power For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
For 750 W Power Supply:
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
For 460 W Power Supply:
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an altitude derating of
1.0°C per every 304.8 m (1.8°F per every 1000 ft) above sea
level to a maximum of 3048 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr (18°F/hr). The
upper limit may be limited by the type and number of options
installed.
System performance may be reduced if operating with a fan
fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr
(36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet
bulb temperature, non-condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet
bulb temperature, non-condensing.
QuickSpecs
HP ProLiant DL560 Generation8 (Gen8)
Technical Specifications
DA - 14395   North America — Version 8 — December 10, 2012
Page  44