Zebra HW46211 Manual De Usuario

Descargar
Página de 275
13185L-002 Rev. A  1/24/06
110XiIIIPlus Maintenance Manual
Page 4-35
Maintenance
Section 4
4. Adjust the printhead position by turning equally the two screws located at the back 
of the print mechanism. Turn both screws one-eighth of a turn clockwise and 
observe the changes in print quality. Turn both screws one-sixteenth of a turn 
counterclockwise and observe the changes in print quality. Due to spring pressure, 
there may be a dead spot in the actual printhead movement when changing 
adjustment direction.
5. Continue to make small adjustments in both directions until the best quality is 
achieved.
6. Enter Configuration Mode and decrease the darkness setting until the Pause Key 
Self Test labels are a charcoal-gray color.
7. Inspect the test labels for streaks, flowering, and other print quality problems.
8. If required, adjust the printhead position until print quality problems are corrected.
9. Enter Configuration Mode and increase the darkness until the Pause Key Self Test 
labels are printed at optimum resolution and contrast.
10. When acceptable print quality is achieved, tighten the four screws at the top of the 
printhead. 
11. Run additional Pause Key Self Test labels to verify proper positioning.
Notes • Make very small adjustments and check the results. Turn the screws 
clockwise to move the printhead toward the front of the printer. Turn the screws 
counterclockwise to move the printhead toward the back of the printer.
Special tool (Zebra part number 11301) allows adjustment of the printhead 
location screws while the printer is running.