Zebra HW46211 Manual De Usuario

Descargar
Página de 275
Page 4-76
110XiIIIPlus Maintenance Manual
13185L-002 Rev. A  1/24/06
Section 4
Maintenance
Install the Sensor 
1. Insert the upper take-label sensor connector and cable through the upper hole in the 
main frame.
Figure 4-49.   Take-Label Sensors
2. Install the sensor with the window facing down. Secure the sensor to the main frame 
with screw.
3. Insert the lower take-label sensor connector and cable through the lower hole in the 
main frame.
4. Install the sensor with the window facing up. Secure the sensor to the main frame 
with screw.
5. Refer to 
. Route the wires through the cable clamps to the main logic 
board. Ensure that the wires do not come in contact with any moving parts.
6. Connect the upper take-label sensor connector to P2 on the main logic board and the 
lower label available sensor connector to P1.
Note • The upper take-label sensor has green/yellow wires.
Screw
Lower Sensor
Screw
Upper Sensor
Note • The lower take-label sensor has black/red wires.