Zebra HW46211 Manual De Usuario

Descargar
Página de 275
Page 1-10
110XiIIIPlus Maintenance Manual
13185L-002 Rev. A 1/24/06
Section 1
System Description
Cabling Requirements
Data cables must be fully shielded and fitted with metal or metallized connector shells. 
Shielded cables and connectors are required to prevent radiation and reception of electrical 
noise. 
To minimize electrical noise pickup in the cable:
Keep data cables as short as possible.
Do not bundle the data cables tightly with the power cords.
Do not tie the data cables to power wire conduits.
Cable Connections
Parallel Data Port
Refer to 
When communicating via the parallel port, refer to 
 to configure the 
communication parameters for the printer.
Figure 1-5.   Parallel Data Port
Note • Zebra printers comply with FCC “Rules and Regulations,” Part 15, 
Subpart J, for Class A Equipment, using fully shielded 6
′ (2 m) data cables. Use 
of longer cables or unshielded cables may increase radiated emissions above 
the Class A limits.
RS-422 and RS-485 applications should use twisted shielded pairs as 
recommended in the TIA/EIA-485 specifications.
10 ft (4.5 m) maximum
25-pin
male
Computer
Printer
36-pin
male
PC
25-pin
female