Maintenance
Coax Communications Interface Boards
Install
1. Refer to
. Turn the power Off (O) and disconnect the AC
power cord. Disconnect the data cable.
2. Refer to
and remove the electronics cover.
3. Refer to
. At the rear of the printer, remove and retain the two screws
and the blank cover plate or existing interface board positioned next to the main
RS-232 and parallel interface connectors.
RS-232 and parallel interface connectors.
Figure 4-72. Coax Communications Interface Board Installation
4. Plug the 40-pin interface data cable into the keyed interface data cable connector
P21on the main logic board.
Caution:
The printer electronics are susceptible to static discharge. Before proceeding, it
is highly recommended the technician wear an antistatic wrist strap connected
to the printer chassis.
is highly recommended the technician wear an antistatic wrist strap connected
to the printer chassis.
Caution:
Unless indicated otherwise, turn the printer Off (O) and disconnect the printer
from the power source before performing the following maintenance.
from the power source before performing the following maintenance.
Caution:
This installation must be performed by a qualified service technician.
Data Cable
Connector
Ribbon Cable