Deployment Details
August 2012 Series
22
Cisco TelePresence
MCU
MCU
High-definition
participants
participants
Standard-definition
endpoints
endpoints
CTI-4501
6
12
CTI-4505
12 at 720p30
6 at 1080p30
6 at 720p60
6 at 1080p30
6 at 720p60
24
CTI-4510
20 at 720p30
10 at 1080p30
10 at 720p60
10 at 1080p30
10 at 720p60
40
CTI-4515
30 at 720p30
15 at 1080p30
15 at 720p60
15 at 1080p30
15 at 720p60
60
CTI-4520
40 at 720p30
20 at 1080p30
20 at 720p60
20 at 1080p30
20 at 720p60
80
If your organization plans to make extensive use of reservationless confer-
ences, Cisco recommends separating the two conference types onto two
MCUs. Separating the two conference types prevents reservationless
conferences from using all of the resources on the MCU that supports
scheduled conferences.
ences, Cisco recommends separating the two conference types onto two
MCUs. Separating the two conference types prevents reservationless
conferences from using all of the resources on the MCU that supports
scheduled conferences.
Scheduled conference calls are created on Cisco MCU for call-in and call-
out types of meetings. Before getting started, you need to collect certain
information specific to your site. You can fill in the following table.
out types of meetings. Before getting started, you need to collect certain
information specific to your site. You can fill in the following table.
Table 3 - Information you need before configuring Cisco MCU
Item
Cisco SBA
configuration
configuration
Site-specific
details
details
IPV4 address
10.4.48.135
IPV4 subnet
255.255.255.0
IPV4 default gateway
10.4.48.1
Host name
MCU
DNS server address
10.4.48.10
DNS local host name
MCU
DNS domain name
cisco.local
NTP server address
10.4.48.17
Time zone
Pacific -8
SNMP read-only community
cisco
SNMP read/write community
cisco123
SNMP trap community
cisco
Remote syslog server
10.4.48.13
Procedure 1
Configure MCU connectivity to the LAN
The MCU can be connected to a Nexus switch in the Data Center or a
Catalyst switch in the Server Room. In both cases, QoS policies are added
to the ports to maintain video quality during conferences. Please choose the
option that is appropriate for your environment.
Catalyst switch in the Server Room. In both cases, QoS policies are added
to the ports to maintain video quality during conferences. Please choose the
option that is appropriate for your environment.
Option 1. Connect the MCU to a Nexus 2248UP
Step 1:
Login to the Nexus switch with a username that has the ability to
make configuration changes.
Step 2:
If there is a previous configuration on the switch port where the
MCU is connected, remove the individual commands by issuing a
no
in front
of each one to bring the port back to its default state.