Fujitsu 600GB 2.5" 10k SAS SED FTS:ETED6HE-L Manual De Usuario
Los códigos de productos
FTS:ETED6HE-L
Disk Drive(3.5inch)
1TB 7.2krpm x6
(RAID1+0)
for DX80 S2/DX90 S2
ETCN1SD
Y
N
N
Y
Y
N
N
Y
Y
N
N
N
N
Y
N
Y
N
Currently
Available
RAID1+0(3D+3M)
•
3.5" Nearline SAS disk drive (1TB/7.2krpm) x 6
Disk Drive(3.5inch)
2TB 7.2krpm x6
(RAID1+0)
for DX80 S2/DX90 S2
ETCN2SD
Y
N
N
Y
Y
N
N
Y
Y
N
N
N
N
Y
N
Y
N
Currently
Available
RAID1+0(3D+3M)
•
3.5" Nearline SAS disk drive (2TB/7.2krpm) x 6
Disk Drive(3.5inch)
3TB 7.2krpm x6
(RAID1+0)
for DX80 S2/DX90 S2
ETCN3SD
Y
N
N
Y
Y
N
N
Y
Y
N
N
N
N
Y
N
Y
N
Currently
Available
RAID1+0(3D+3M)
•
3.5" Nearline SAS disk drive (3TB/7.2krpm) x 6
SSD(3.5inch) 100GB x6
(RAID1+0)
for DX80 S2/DX90 S2
ETCS1SD
Y
N
N
Y
Y
N
N
Y
Y
N
N
N
N
Y
N
Y
N
Currently
Available
RAID1+0(3D+3M)
•
3.5" SSD (100GB) x 6
•
SLC type
SSD(3.5inch) 200GB x6
(RAID1+0)
for DX80 S2/DX90 S2
ETCS2SD
Y
N
N
Y
Y
N
N
Y
Y
N
N
N
N
Y
N
Y
N
Currently
Available
RAID1+0(3D+3M)
•
3.5" SSD (200GB) x 6
•
SLC type
SSD(3.5inch) 400GB x6
(RAID1+0)
for DX80 S2/DX90 S2
ETCS4SD
Y
N
N
Y
Y
N
N
Y
Y
N
N
N
N
Y
N
Y
N
Currently
Available
RAID1+0(3D+3M)
•
3.5" SSD (400GB) x 6
•
SLC type
SSD(3.5inch) 800GB x6
(RAID1+0)
for DX80 S2/DX90 S2
ETCS8SD
Y
N
N
Y
Y
N
N
Y
Y
N
N
N
N
Y
N
Y
N
Currently
Available
RAID1+0(3D+3M)
•
3.5" SSD (800GB) x 6
•
MLC type
Power distribution unit
Power distribution unit
for DX80 S2/DX90 S2
(AC200-240V, 1U,
Max 2 enclosures
connection)
ETEP4BU-L
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Currently
Available
•
Power distribution unit (1U) x 1
•
Input AC cable (AC200V - 240V,
IEC60320-C13↔NEMA L6-15P: 4m) x 2
IEC60320-C13↔NEMA L6-15P: 4m) x 2
•
Output AC cable
(IEC60320-C13↔IEC60320-C14: 3m) x 4
(IEC60320-C13↔IEC60320-C14: 3m) x 4
•
Connects to any of the 2
controller enclosure/drive enclosures
controller enclosure/drive enclosures
•
Input AC cable plug shape: NEMA L6-15P
Power distribution unit
for DX80 S2/DX90 S2
(AC200-240V, 2U,
Max 6 enclosures
connection)
ETEP12U-L
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Currently
Available
•
Power distribution unit (1U) x 2
•
Input AC cable (AC200V - 240V,
direct connection↔NEMA L6-20P: 4m) x 2
direct connection↔NEMA L6-20P: 4m) x 2
•
Output AC cable
(IEC60320-C13↔IEC60320-C14: 3m) x 12
(IEC60320-C13↔IEC60320-C14: 3m) x 12
•
Connects to any of the 6
controller enclosure/drive enclosures
controller enclosure/drive enclosures
•
Input AC cable plug shape: NEMA L6-20P
Power distribution unit
for DX80 S2/DX90 S2
(AC200-240V, 2U,
Max 8 enclosures
connection)
ETEP16U-L
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Currently
Available
•
Power distribution unit (1U) x 2
•
Input AC cable (AC200V - 240V,
direct connection↔NEMA L6-30P: 4m) x 2
direct connection↔NEMA L6-30P: 4m) x 2
•
Output AC cable
(IEC60320-C13↔IEC60320-C14: 3m) x 16
(IEC60320-C13↔IEC60320-C14: 3m) x 16
•
Connects to any of the 8
controller enclosure/drive enclosures
controller enclosure/drive enclosures
•
Input AC cable plug shape: NEMA L6-30P
Extension QSFP cable between enclosures
Extension QSFP cable
between enclosures
for DX80 S2/DX90 S2
(3m)
ETEC1Q3-L
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Currently
Available
•
QSFP cable (3m) x 1
•
Must be ordered when the QSFP cable
supplied with the drive enclosure (0.75m) is
supplied with the drive enclosure (0.75m) is
too short to connect
Product name
Product ID
Pr
ei
ns
ta
lled (
**)
Product ID
EOL
Component items
ET
082D
CC
U
ET
082S
CC
U
ET
082D
D
CU
ET
082S
D
CU
ET
092D
CC
U
ET
092S
CC
U
ET
092D
D
CU
ET
092S
D
CU
ET
CA
D
2C
U
ET
CA
D
2C
U
-L
ET
CA
D
1C
U
ET
CA
D
1C
U
-L
ET
CA
D2
DU
ET
CA
D2
DU
-L
ET
CA
D1
DU
ET
CA
D1
DU
-L
Y: Supported
N: Not supported
–: Not applicable
** Y: Preinstalled at the factory (must be ordered with the DX80 S2/DX90 S2)
N: Not preinstalled at the factory (packaged separately)