2.FUNCTIONS
Control Resistance of R sensor OFF Point 
 
- When the refrigeration of refrigerator is poor or weak though Fan and COMP are working continuously, 
   the following actions are recommended for service. 
    (1) Resistance (R25) :  Default resistance (31.4Kohms) 
    
(2) Resistance (R26) :  Cut the “J1” off to reduce basic resistance by 1.5
°
C. (2Kohms up) 
    
(3) Resistance (R27) :  Cut the “J2” off additionally to reduce basic resistance by 1.5
°
C. (total 4Kohms up) 
      
     
 R25 = R-SENSOR OFF point 
          R25 + R26 = R-SENSOR OFF point - 1.5
°
          R25 + R26 + R27 = R-SENSOR OFF point - 3
°
 
         
 
    
 
CONTROL OBJECT 
INPUT 
 
”J1” , “J2”  On Main PCB 
 
 2-8. Control of R-sensor OFF Point
 