Cisco 2-Port RJ-48 Multiflex Trunk- E1 (Voice & WAN) VWIC-2MFT-E1= Hoja De Datos
Los códigos de productos
VWIC-2MFT-E1=
© 2004 Cisco Systems, Inc. All right reserved.
Important notices, privacy statements, and trademarks of Cisco Systems, Inc. can be found on cisco.com
Page 13 of 15
Product Number
Description
Line Bit Rate
J1 2.048Mbps
Line Code
CMI (Coded Mark Inversion)
Framing Format
Eight Frame Multiframe J1 TTC JJ-20.11
Output level (LBO)
2.55 (min), 3.3 (typ) and 3.9 Max Vp-p
Input Level
Greater than 0.2 Vp-p and Less than 4 Vp-p
Diagnostic Loopback Support
Line Loopback, Local Loopback and Isolation Loopback.
Alarm Detection
Monitors for Loss of Signal, Out of Frame/Loss of Lock and Yellow Alarm. If any of these conditions are
present, the alarm LED (labeled AL) on the NM-HDV faceplate will be lit.
LED Indicators
Data Carrier Detect (CD)
Loopback (LP)
Alarm (AL)
Physical Interface Standards
TTC JJ.20.10-11
HOMOLOGATION
The IP Communications High-Density Digital Voice Network Modules are approved for the countries listed below. The approvals are for off-
premise and on-premise connections, unless stated otherwise. Approval for other countries is in progress. Please refer to the homologation
Website shown below for approval progress for other countries and the VIC/VWIC cards used in the NM-HDV2:
http://tools.cisco.com/cse/prdapp/jsp/externalsearch.do?action=externalsearchresult&page=EXTERNAL_SEARCH
Table 10.
Country
Specification
Approval
United States
•
EMC 47CFR15 Subpart B 2002, T1
•
Safety IEC60950
•
Telecom 47 CFR part 68, TIA/EIA 968-A
Supported
Canada
•
EMC CISPR22 or FCC Part 15
•
Safety IEC60950
•
Telecom CS-03
Supported
European Community (CE) Countries
1
•
EMC EN55022/EN50082/EN61000
•
Safety EN60950
•
Telecom TBR4, TBR12 and TBR13
Supported
1.
CE (European Community) countries: Austria, Belgium, Denmark, Finland, France, Germany, Gibraltar, Greece, Ireland, Italy, Liechtenstein, Luxembourg,
Malta, Monaco, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland, United Kingdom.