Installation manual Integral 5 D/E easy
PB1 (emergency power supply)
Further information on the charging phase
In the event of power failure or removal of the plug-in mains unit, the PABX Integral 5 is powered
from battery; the battery discharges.
The discharge phase begins (4); the number of flash pulses changes during the discharge phase.
The start of the discharge phase (c) is signalled by a flash pulse, LED 5sec. off -> 1 pulse --> LED
The discharge phase begins (4); the number of flash pulses changes during the discharge phase.
The start of the discharge phase (c) is signalled by a flash pulse, LED 5sec. off -> 1 pulse --> LED
5 sec. off -> 1 pulse etc.
The end of the discharge phase (d) is signalled by x
The end of the discharge phase (d) is signalled by x
n
pulses, LED 5 sec. off -> x
n
pulses -> LED
5 sec. off -> x
n
pulses etc.
If point d is reached, the PB1 switches off (protection against total discharge).