Bosch DS415I Manual De Usuario
Intrusion Alarm Systems | DS415i and DS435i Single Beam Photoelectric Detectors
DS415i and DS435i Single Beam
Photoelectric Detectors
www.boschsecurity.com
u
150 m (500 ft) range
u
Friction lock optics
u
Alarm retransmission
u
Alarm memory (DS435i only)
u
Inhibit wiring (DS435i only)
This single-beam photoelectric detector series
consists of the surface mount DS415i and DS435i
Detectors with their separate transmitters and
receivers. The transmitter emits one invisible infrared
beam to the receiver. If the beam is broken, the
receiver signals an alarm. The detectors operate in
either AC/DC or DC-only mode according to the
following table:
consists of the surface mount DS415i and DS435i
Detectors with their separate transmitters and
receivers. The transmitter emits one invisible infrared
beam to the receiver. If the beam is broken, the
receiver signals an alarm. The detectors operate in
either AC/DC or DC-only mode according to the
following table:
Product
AC
DC
DS415i Detector
•
•
DS415iDC Detector
•
DS435i High Performance Detector
•
Functions
Alarm Memory (DS435i only)
Provides indication of stored alarms for use in multiple
unit applications by latching the alarm LED at the
receiver. Controlled by a switched voltage from the
control panel.
unit applications by latching the alarm LED at the
receiver. Controlled by a switched voltage from the
control panel.
Alarm Retransmission
Supervised alarm circuit transmitter that allows
connection of normally open or normally closed
devices such as magnetic contacts or relays from other
detectors. Their condition is relayed to the receiver by
transmitter shutdown.
connection of normally open or normally closed
devices such as magnetic contacts or relays from other
detectors. Their condition is relayed to the receiver by
transmitter shutdown.
Inhibit Wiring (DS435i only)
Optional signal synchronization wire between
transmitter and receiver. Prevents receiver from being
activated by other sources such as another
transmitter. Units must have a common ground
connection.
transmitter and receiver. Prevents receiver from being
activated by other sources such as another
transmitter. Units must have a common ground
connection.
Test Features
• Alarm LED
• Margin test switch to assist with alignment
• Margin test switch to assist with alignment
Certifications and approvals
Region
Certification
USA
UL
DS415i and DS435i: ANSR: Intrusion
Detection Units (UL639)
Canada
ULC
ANSR7.BP1448 Intrusion-detection
Units Certified for Canada