Cisco Catalyst 4500 1300 W Redundant AC Power Supply (PoE) PWR-C45-1300ACV/2 Hoja De Datos

Los códigos de productos
PWR-C45-1300ACV/2
Descargar
Página de 10
 
 
Data Sheet 
© 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. 
Page 6 of 10 
Power Supply 
1000 WAC             (PWR 
C45-1000AC) 
1400 WAC              
(PWR C45-1400AC) 
1400W Triple Input DC 
(PWR-C45-1400DC) 
Output current (data) 
12V at 83.4A 
3.3V at 12.2A 
12V at 113.4A 
3.3V at 12.2A 
Two –48 VDC at 15A 
One –48 VDC at 12.5A 
Output current (PoE) 
– 
– 
– 
Output power redundant mode 
(data) 
1000W + 40W 
1360W + 40W 
1368W + 40W 
Output power redundant mode 
(PoE) 
– 
– 
– 
Output power combined mode 
(data) 
1667W 
– 
– 
Output power combined mode 
(PoE) 
– 
– 
– 
Heat dissipation 
943 BTU/hr 
1048 BTU/hr 
1048 BTU/hr 
Holdup time 
20 ms 
20 ms 
4 ms 
Table 9. 
Cisco Catalyst 4500 E-Series Power-Supply Specifications (Data and Voice) 
 
 
1300 WACV 
(PWR C45-
1300ACV) 
2800 WACV 
(PWR C45 
2800ACV) 
1400 WDC-P 
(PWR C45-
1400DC-P) 
4200 WACV 
PWR C45-
4200ACV) 
6000 WACV 
(PWR-C45-
6000ACV) 
2500W (PWR-
4502) 
 
Minimum Cisco 
IOS
®
 Software 
Release required 
12.1(12c)EW 
12.1(12c)EW 
12.1(13)EW 
12.2 
12.2(52)SG 
12.1(13)EW 
Minimum Cisco 
Catalyst Operating 
System Software 
required 
7.4(1) 
7.4(1) 
7.5(1) 
– 
– 
7.5(1) 
Integrated PoE 
Yes (up to 
800W) 
Yes (up to 
1400W) 
Up to 7500W 
(minus power 
consumed for 
data) when 
connected 
directly to DC 
power plant or 
2 external AC 
power shelves 
Yes (up to 
3855W) 
Yes (up to 
4800W) 
2500W per 
power supply 
IEEE 802.3af 
compliant 
Yes 
Yes 
Yes 
Yes 
Yes 
Yes 
Input current 
(rated) 
16A at 100 
VAC 
7A at 240 VAC 
16A at 200 
VAC 
Data: 31A at –
60 VDC 
Inline: 180A at 
–48VDC 
Two 12A at 100 
VAC or 
Two 12A at 200 
VAC 
Two 12A at 100 
VAC or 
Two 16A at 200 
VAC 
15A at 200 
VAC 
Output current 
(data) 
12V at 84.7A 
3.3V at 12.5A 
12V at 113.3A 
3.3V at 12.1A 
12V at 120A 
3.3V at 10A 
12V at 115.3A 
3.3V at 12.5A 
12V at 186.9A 
3.3V at 12.5A 
–52 VDC at 
50A (total 
output per 
supply) 
Output current 
(PoE) 
–50V at 16.7A 
–50V at 28A 
–48 or –60 
VDC at 140A 
–50V at 77.1A 
(200V) 
–50V at 38A 
(100V) 
-50V at 100.0A 
(200V) 
-50V at 38.5A 
(120V) 
–52 VDC at 
50A (total 
output per 
supply) 
Output power 
redundant mode 
(data) 
1000W + 40W 
1360W + 40W 
1367W + 40W 
1383W + 40W 
2200W + 40W 
Up to 1400W 
(through DC 
supply) 
Output power 
redundant mode 
(PoE) 
800W 
maximum per 
power supply 
1400W 
maximum per 
power supply 
Up to 7500W 
(minus the 
power 
consumed for 
data) 
3700W (220V) 
1850W (110V) 
4800W (220V) 
1850W (110V) 
2500W per 
supply (minus 
the power 
consumed for 
data) 
Output power 
combined mode 
(data) 
1667W 
2473W 
2734W 
2766W 
4400W 
1360W 
Output power 
combined mode 
(PoE) 
1333W 
(maximum) 
2333W 
7280W 
6700W (220V) 
3360W (110V) 
8700W (220V) 
3360W (110V) 
–