B&B Electronics ESR902 Prospecto

Descargar
Página de 2
ESR90x-2213ds-2/2 
 
 
 
Operation 
 
A detailed operating manual is contained on the CD ROM which ships with the product. 
 
 
Vlinx 
TM 
Manager Software allows easy access to the serial server to configure the server and its 
ports, upgrade server firmware and monitor port status and activity. When the Vlinx Manager opens 
it will search for and display all serial servers on the network. The Monitor Port feature allows you to 
use any PC on the LAN/WAN to actively view and troubleshoot the communications status. It 
shows when there is a client connection to the server and the client IP address. It displays the 
number of bytes transmitted and received as well as the status of the hardware handshaking lines 
 
 
ESR serial servers can be accessed and configured from any web browser (such as Internet 
Explorer) on the LAN/WAN. This allows you to remotely manage the software and your serial 
device. It also allows off-site troubleshooting 
 
 
Vlinx Serial Servers provide automatic resumption of the TCP data connection in case of a power 
failure or loss of an Ethernet connection on either the client or server. Once the Heartbeat 
connection is established, the server sends a signal to the client every five seconds until 
communication is re-established. Without this feature a device that loses a connection and stops 
communicating would not be able to reconnect without a person attending to the problem. The 
Heartbeat feature works with virtual COM and TCP direct IP connections. 
  
 
Specifications 
 
Serial 
 
Ethernet 
 
 
 
Serial Interfaces: 
RS-232 (DTE), RS-422, RS-485 (2/4-Wire) 
 
Connector: 
RJ-45 F 
Serial Connectors: 
ESR901: TB and DB9 M (selectable) 
 
Data Rate: 
10/100 Mbps Auto-detecting 10BaseT or  
 
ESR902: 2 x DB9 M 
 
 
1000BaseTx 
 
ESR904: 4 x DB9 M 
 
Protocols: 
TCP, IP, ARP, DHCP, Telnet, HTTP, UDP 
Baud Rate: 
110 to 230.4 kbps 
 
 
ICMP 
Parity: 
None, Even, Odd, Mark, Space 
 
Configuration 
 
Data Bits: 
5, 6, 7, or 8 
 
Console: 
RS-232 w/ VT100 Emulation 
Stop Bits: 
1, 1,5, or 2 
 
Telnet: 
HyperTerminal w/VT100 Emulation 
Serial Buffer 
8 kb per port 
 
ESP Manager: 
Compatible w/Win98, ME, 2000, 2003, XP, 
Note: Refer to the manual for pin-outs and signals. 
 
 
NT, and Vista 
 
 
HTTP: 
Embedded Web Page 
 
 
 
 
 
Power 
 
Environment 
 
 
 
Voltage: 
9 to 48 VDC or 8 to 24 VAC 
 
Operating Temp: 
-14 to 176 F (-10 to 80 C) 
Power Consumption: 
ESR901: 320 mA @ 12 VDC 
 
Storage Temp: 
-4 to 185 F (-20 to 85 C) 
 
ESR902: 340 mA @ 12 VDC 
 
Humidity:  
5 to 95% Non-condensing 
 
ESR904: 326mA @ 12 VDC 
 
Dimensions  
 
Connector: 
Removable Terminal Block 
 
ESR901/902: 
1.75 x 6.1 x 4.1 in 
 
 
 
 
(4.46 x 15.52 x 10.46 cm) 
 
 
 
ESR904: 
1.75 x 7.1 x 4.1 in 
 
 
 
 
(4.46 x 18.03 x 10.46 cm) 
 
 
 
Enclosure: 
IP 30 
 
 
 
Approvals:  
CE, FCC