Gigaset HC450 S30852-H1799-R101 Manual De Usuario
Los códigos de productos
S30852-H1799-R101
8
Installing the Gigaset HC450 door intercom system
Gigaset HC450 / en / A31008-M1799-R101-1-7619 / Starting.fm / 13.02.2007
Ve
rs
ion 4,
16
.09.
2005
Surface mounting
u Remove the bell button if there is one
and unscrew the cables. Fit the frame
over the cable outlet. Next screw one
of the enclosed green clamping plugs
to the existing 2-core bell cable (polar-
ity is not relevant here) and insert it
in the jack with the ETS symbol
(green jack).
u Hang the door intercom at the top of
the frame (45 degree angle, see illus-
tration on right) and lower it against
the wall. Fix the door intercom using
the two enclosed hexagon socket
screws.
Connecting a door opener (optional)
The door opener is connected to the
appropriate jack of the door intercom
using a 2-core cable and the blue
clamping plug.
Caution:
If you are using the existing bell cable, the
doorbell system must be set to zero potential
prior to installation.
Caution:
Cables must not be connected or disconnected
during a thunderstorm.
Door intercom
Door opener
Light
Actuator
ETS
Control unit
Cable plug