Mitel Networks 3300 CX II 50006093 Hoja De Datos

Los códigos de productos
50006093
Descargar
Página de 6
DATA SHEET  | MITEL MiVOICE BUSINESS 3300 CONTROLLERS
MITEL MiVOICE BUSINESS 3300 CONTROLLERS   |   5
SPECIFICATION
3300 CONTROLLER
ANALOG SERVICES 
UNIT (ASU)
NETWORK SERVICES 
UNIT (NSU)
STREAMLINE
Temperature
40° to 122°F  
(4° to 50°C)
40° to 122°F  
(4° to 50°C)
40° to 122°F  
(4° to 50°C)
(10°C to 50°C)
Humidity
5% to 95%  
relative humidity,  
non-condensing
5% to 95%  
relative humidity,  
non-condensing
5% to 95%  
relative humidity,  
non-condensing
10% to 95%  
relative humidity,  
non- condensing
Max. Heat Dissipation – fully loaded
CX II / CXi II – 170 BTUs 
per hour MXe III– 750 
BTUs per hour AX –  
1024 BTUs per hour
ASU – 170 BTUs per 
hour ASU II – 260 BTUs 
per hour
60 BTUs per hour
24-Port: 61 BTUs per 
hour 48-Port: 81 BTUs 
per hour
Air Flow
46 cubic ft. / min. at 
maximum output of  
fans AX – 110 cubic ft.
Acoustic Emissions
Max 50dBA continuous, 
75dBA intermittent 
(<10% duty cycle)
OPERATIONAL ENVIRONMENT
Conversion factors: One watt is equal to 3.412 BTUs per hour. One ton of refrigeration is equal to 12,000 BTUs per hour or 3.516 Kilowatts, and 0.75 kilowatt-hour is equal to one ton  
of refrigeration.
SPECIFICATION
3300 CONTROLLER
ANALOG SERVICES 
UNIT (ASU)
NETWORK SERVICES 
UNIT (NSU)
STREAMLINE
Input / Disconnect
IEC320-C14 Class 1 
AC Receptacle 2 AC 
Receptacles on AX  
and MXe III with 
redundant power
IEC320-C14 Class 1  
AC Receptacle
IEC320-C14 Class 1  
AC Receptacle
IEC320-C14 Class 1  
AC Receptacle
Input Voltage / Frequency Rating
100 – 240 VAC  
50 / 60 Hz
100 – 240 VAC  
50 / 60 Hz
100 – 240 VAC  
50 / 60 Hz
100 – 240 VAC  
50 / 60 Hz
Input Power
CX II / CXi II – 250 W 
MXe III – 200 W MXe III 
Expanded – 250 W  
AX – 300 W
ASU – 75 W max  
ASU II – 125 W max
NSU – 20 W R2  
NSU – 30 W
24-Port: 16.5W  
48-Port: 22W
AC Source
90 – 264 VAC
90 – 264 VAC
90 – 264 VAC
90 – 264 VAC
Frequency Range
47 – 63 Hz
67 – 63 Hz
67 – 63 Hz
67 – 63 Hz
SYSTEM INPUT POWER REQUIREMENTS
9