Pull the cover ① and ②in the directions as shown by
arrows to remove the cover.
arrows to remove the cover.
13.2.4 ELECTRICAL WIRING FOR FLOOR TYPE
INDOOR UNIT
WARNING:
–
–
The appliance must be earthed
–
Remove the cover of the electric box.
–
Connect the connecting cords
–
Assemble the cover of electric box
•
Applicable Models :
RAF-25QXA/RAF-35QXA/RAF-50QXA
WARNING:
–
–
Leave some space in the connecting cord for
maintenance purpose and be sure to secure it with the
cord band.
maintenance purpose and be sure to secure it with the
cord band.
–
Secure the connecting cord along the coated part of
the wire using the cord band. Do not exert pressure on
the wire as this may cause overheating of fire
the wire using the cord band. Do not exert pressure on
the wire as this may cause overheating of fire
Connection of connecting cord
Connect the
earth cord
earth cord
After remove the screw and cover and
putt the connecting cords and fix the
cover with screws
putt the connecting cords and fix the
cover with screws
After remove the screw and
cover, and put the
connecting cords and fix
the cover with screw
cover, and put the
connecting cords and fix
the cover with screw
Connect
the cord
the cord
Securely screw in the connecting
cord so that it will not get loose or
disconnect.
Tightening torque reference value:
1.2 ~ 1.6Nm (12~16kgf.cm)
Excessive tightening may damage
the interior of the cord requiring
replacement
cord so that it will not get loose or
disconnect.
Tightening torque reference value:
1.2 ~ 1.6Nm (12~16kgf.cm)
Excessive tightening may damage
the interior of the cord requiring
replacement
Connecting cord
Connect the
earth cord
earth cord
After remove the screw
and cover, and put the
connecting cords and fix
the cover with screws
and cover, and put the
connecting cords and fix
the cover with screws
D
C
C
D
C
D