Calculated Industries ElectriCalc Pro 5070 Prospecto

Los códigos de productos
5070
Descargar
Página de 1
Model 5070
Calculator Features:
•  Wire Sizes
•  Integrated Voltage Drop
•  Conduit Sizing
•  Motor Full-Load AMPs
•  Fuse and Breaker Sizes
•  Parallel and Derated  
Wire Sizing
•  Service and Equipment 
Grounding Conductor Sizes
4840 Hytech Drive
Carson City, NV 89706
1-800-854-8075
Visit our website at:
www.calculated.com
Wire Sizes, Integrated Voltage Drop,
Conduit Sizing
Motor Full-Load AMPs, 
Fuse and Breaker Sizes
NEC
®
 Tables Show for 
Wire Size Calculations
Service and Equipment
Grounding Conductor Sizes
The 
ElectriCalc Pro
 is the world’s most complete Code-based electrical 
calculator. Solve electrical calculations in seconds; answers conform to 
current NEC
®
. It’s a complete electrical reference tool that will save time  
and money. 
Update to future code revisions with an easy-to-install kit.
Dedicated Keys and Functions Make It Easy To Use!
National Electrical Code® and NEC® are registered trademarks of the National Fire Protection Association, Inc., Quincy, MA 02269.
5070-SPEC-E-4C-04_14
Electrical Code Calculator Compliant with  
2014, 2011, 2008, 2005, 2002, 1999 and 1996 NEC
®
Electrical Contractors • Designers • Engineers • Electricians • Maintenance
Inspectors • Planners • Builders • Lighting Specialists
Protective hard
case with 
soft-grip and 
tough 360° 
flip-top cover
NEC
®
COMPLIANT
 
Solve Electrical 
Calculations in  
Seconds!
ARMADILLO GEAR™
INCLUDED
Wire Types — Calculates 
wires in Raceways and 
cross-sectional wire areas.
Conduit Size — Find 
conduit sizes based on total 
area of entered wire types 
and sizes.
HP Motor — Enters or 
calculates motor horsepower.
Dual Element Fuse — 
Calculates minimum amp 
rating for Dual Element 
Fuse, full-load current 
percent multiplier.
HP Theoretical —  
Enters or calculates
theoretical horsepower.
Set — Accesses 
secondary functions.
Includes a rugged, shock, 
dust and moisture resistant 
Armadillo Gear case.
Inverse Time — 
Calculates the minimum 
amp rating for an Inverse 
Time Breaker.
Voltage Drop — Enters 
or calculates voltage drop 
and actual percentage.
Overload — Displays the 
overload amperage based 
on the full-load current on 
motor nameplate.
Length — Enters or 
calculates the length of a run 
for voltage drop calculation.
Wire Sizes — Enters or 
calculates wire sizes based 
on ampacity and voltage 
drop for Ground, Derated, 
Parallel and Motor, etc.
Preferences — Used to 
set default settings or modes, 
including NEC Code Year.
Electrical Units — Enters 
or solves electrical values.