Intel® Server Board S1400SP TPS 
Appendix B: Integrated BMC Sensor Tables 
Revision 1.0 
 
Intel order number G64248-001 
111 
Table 61. Integrated BMC Core Sensors
 
Full Sensor Name 
(Sensor name in 
SDR) 
 
Sensor # 
Platform 
Applicability 
Sensor Type 
Event/Reading 
Type 
Event Offset Triggers  Contrib. To 
System 
Status 
Assert/De-
assert 
Readable 
 Value/ 
Offsets 
Event 
Data 
Rearm  Standby 
Power Unit 
Status 
(Pwr Unit Status) 
01h 
All 
Power Unit 
09h 
Sensor 
Specific 
6Fh 
00 - Power down 
OK 
As and 
De 
– 
Trig 
Offset 
02 - 240 VA power 
down 
Fatal 
04 - A/C lost 
OK 
05 - Soft power 
control failure 
 
Fatal 
06 - Power unit 
failure 
Power Unit 
Redundancy1 
(Pwr Unit 
Redund) 
02h 
Chassis-
specific 
Power Unit 
09h 
Generic 
0Bh 
00 - Fully 
Redundant 
OK 
As and 
De 
– 
Trig 
Offset 
01 - Redundancy 
lost 
Degraded 
02 - Redundancy 
degraded 
Degraded 
03 - Non-
redundant: 
sufficient 
resources. 
Transition from full 
redundant state. 
Degraded 
04 – Non-
redundant: 
sufficient 
resources. 
Transition from 
insufficient state. 
Degraded 
05 - Non-
redundant: 
insufficient 
resources 
Fatal