Rigol MSO1074Z-S 4-channel oscilloscope, Digital Storage oscilloscope, MSO1074Z-S Manual De Usuario

Los códigos de productos
MSO1074Z-S
Descargar
Página de 172
RIGOL 
DS1000Z Programming Guide 
2-45
 
:MASK Commands 
 
:MASK commands are used to set and query the parameter in pass/fail test.   
 
Command List: 
  :MASK:X 
  :MASK:Y 
 
 
:MASK:ENABle 
Syntax 
:MASK:ENABle <bool> 
:MASK:ENABle? 
Description 
Enable or disable the past/fail test or query the status of the past/fail test.   
Parameter 
Name 
Type 
Range 
Default 
<bool> 
Bool 
{{0|OFF}|{1|ON}} 
0|OFF 
 
Explanation 
The past/fail test is invalid in the following conditions: the horizontal timebase is XY or 
ROLL, slow sweep mode (namely when the horizontal timebase is YT, the horizontal 
timebase is set to 200ms/div or more slowly) as well as recording waveform. 
Return 
Format 
The query returns 0 or 1.   
Example 
:MASK:ENABle ON