TECHNICAL DATA
Symbol
Max. 40000 counts (characters)
Measuring rate
approx. 2-3 measurements/second, Bargraf approx. 
10 measurements/second
Measuring line length
approx. 90 cm each
Measuring impedance
>10M
Ω (V range)
Operating voltage
9V block battery
Working conditions
0 to 30°C (<75%rF), >30 to 40°C (<50%rF)
Operating altitude
max. 2,000 m
Storage temperature
-10°C to +50°C
Weight
approx. 380 g
Dimensions (LxWxH)
185 x 91 x 43 (mm)
Over-voltage category
CAT III 1,000 V, CAT IV 600 V, contamination degree 2
Measurement tolerances
Statement of accuracy in 
± (% of reading + display error in counts (= number of smallest points)). The accuracy is valid 
for one year at a temperature of +23°C 
± 5°C, and at a relative humidity of less than 75 %, non-condensing. 
Temperature coefficient: +0.1 x (specified accuracy)/1°C
Direct voltage
Range
Accuracy
Resolution
400 mV
±(0,03% + 10)
0,01 mV
4 V
±(0,05% + 10)
0,0001 V
40 V
0,001 V
400 V
0,01 V
1000 V
0,1 V
Overload protection 1000 V; Impedance: 10 M
Ω
Alternating voltage
Range
Accuracy
Resolution
Frequenz range
4 V
0,0001 V
±(0,5 % + 40)
45 Hz - 1kHz
±(1,2 % + 40)
1 kHz - 10 kHz
±(3 % + 40)
10 kHz - 20 kHz
±(4 % + 40)
20 kHz - 100 kHz
40 V
0,001 V
±(0,5 % + 40)
45 Hz - 1kHz
±(1,2 % + 40)
1 kHz - 10 kHz
±(3 % + 40)
10 kHz - 20 kHz
±(6 % + 40)
20 kHz - 100 kHz
400 V
0,01 V
±(0,5 % + 40)
45 Hz - 1kHz
±(1,2 % + 40)
1 kHz - 10 kHz
±(3 % + 40)
10 kHz - 20 kHz
Not specified
20 kHz - 100 kHz
1000 V
0,1 V
±(1,2 % + 40)
45 Hz - 1kHz
±(3 % + 40)
1 kHz - 5 kHz
±(6 % + 40)
5 kHz - 10 kHz
Not specified
10 kHz - 100 kHz
Overload protection 1000 V; Impedance: 10 M
Ω
TrueRMS in the measuring range of 10 – 100%: Crest factor: max. 3.0 (at 750V max. 1.5)