Emmerich Li-Ion manganese battery, ULF 3.6 V 1500 mAh (Ø x H) 18 mm x 65 mm 250848 Hoja De Datos
Los códigos de productos
250848
3
5. Manufacture code
Table5.1 Rank of Capacity
Rank Minimum
Capacity
(mAh)
Maximum Capacity
(mAh)
A 1525
<1550
B 1500
<1525
C 1475
<1500
D 1450
<1475
6. Required functions for charger and required protection functions
To ensure safety, the charger and the protection circuit should be used in combination
with a thermal fuse, positive temperature coefficient thermistor or thermostat. The
standard charging method is CC-CV (Constant Current - Constant Voltage).
6.1 Required functions for charger
No.
Item
Condition
Notes
1
Charging method
CC-CV
2
Maximum charge current
2400 mA
Per cell
3
Rated charge voltage
4.20 V
Per cell
4
Maximum charge voltage
4.25 V
Per cell
5
Timer
5 hours
charge
Current: 50 mA
6
Charge temperature
0~+45 ℃
Blank
Product name
Product lot