Ctek Automatic charger Hochfrequenz-ladegerät 12V, 08/5,0 A MXS 5.0 CHECK Manual De Usuario

Los códigos de productos
MXS 5.0 CHECK
Descargar
Página de 8
EN • 5
EN
CHARGING PROGRAMS AND OPTIONS
Press the MODE-button to select between the charging programs and to add charg-
ing options. The lamps will indicate which programs and options that are selected. The 
selected program will be memorised and restarted next time the charger is connected.
Charging Programs
Program
Battery 
Size (Ah)
Explanation
Temp range
1.2–14Ah
Small battery 
program, 0.8A 
Use for smaller batteries.
-20°C–+50°C 
(-4ºF–122ºF)
14–160Ah
Normal battery 
program, 5A 
Use for normal sized batteries.
-20°C–+50°C 
(-4ºF–122ºF)
Charging Options
Option
Battery 
Size (Ah)
Explanation
Temp range
1.2–160Ah
Cold weather option
Use for charging at low tempera-
tures and for power AGM batteries 
like Optima
®
 and Odyssey
®
. Cold 
weather option increases charging 
voltage
-20°C–+5°C 
(-4ºF–41ºF)
RECOND
1.2–160Ah
Recond option
Use to return energy to empty bat-
teries. Recond your battery once per 
year and after deep discharge to 
maximise lifetime and capacity. The 
Recond option adds STEP 6 to the 
selected charging program. 
-20°C–+50°C 
(-4ºF–122ºF)
BATTERY SIZE (Ah)
TIME TO 80% CHARGED
2Ah
2h
8Ah
8h
20Ah
4h
60Ah
12h
110Ah
26h
READY TO USE
The table shows the estimated time for an empty battery to reach 80% charge level
ERROR LAMP
If the error lamp is lit, check the following:
1.  Is the chargers positive lead connected to the bat-
tery's positive pole?
2. Is the charger connected to a 12V battery?
3.  Has charging been interrupted in STEP 1, 2 or 5?  
Restart the charger by pressing the MODE-button. If charging is 
still being interrupted, the battery... 
STEP 1: ...is seriously sulphated and may need to be replaced. 
STEP 2: ...cannot accept charge and may need to be replaced. 
STEP 5: ...cannot keep charge and may need to be replaced.
MODE
RECOND
12V/5A
MXS 5.0
POWER LAMP
If the power lamp is lit with a:
1.  STEADY LIGHT 
The mains cable is connected to the wall socket.
2.  FLASHING LIGHT 
The charger has entered the energy save mode. This happens if 
the charger isn't connected to a battery in 2 minutes.