TE Connectivity RT33K012 PCB Mount Relay 12Vdc 16A 1 NO, SPST-NO 2-1393240-3 Hoja De Datos
Los códigos de productos
2-1393240-3
Datasheet
Rev. FE1
Issued 2006/05
www.tycoelectronics.com
www.schrackrelays.com
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
change.
General Purpose Relays
1
Power PCB Relay RT1 Inrush
I
1 pole 16 A, 1 CO or 1 NO contact
I
For inrush peak currents up to 80 A
I
Sensitive coil 400 mW
I
5 kV / 10 mm coil-contact
I
Reinforced insulation
I
Ambient temperature 85°C
I
RoHS compliant (Directive 2002/95/EC)
as per product date code 0413
as per product date code 0413
Applications
Domestic appliances, heating control, lighting control
F0177-B
Approvals
V
REG.-Nr. 6106,
Z
E214025
Technical data of approved types on request
Contact data
Contact configuration
1 CO or 1 NO
Contact set
single contact
Type of interruption
micro disconnection
Rated current
16 A
Rated voltage / max.switching voltage AC
240/400 VAC
Limiting continuous current
UL: 20 A
Maximum breaking capacity AC
4000 VA
Limiting making capacity, max 4 s, duty factor 10%
30 A
max 20 ms (incandescent lamps)
80 A
Contact material
AgNi 90/10, AgSnO
2
Mechanical endurance
> 30 x 10
6
cycles
Rated frequency of operation with / without load
6 / 1200 min
-1
Contact ratings
Type
Type
Load
Cycles
RT31K
1000 W incandescent lamp, 250 VAC, NO contact
9x10
4
RT31L
1000 W incandescent lamp, 250 VAC, NO contact
8x10
4
RT31K
16 A, 240 VAC, NO contact, 85°C, VDE/UL508
3x10
4
RT31L
16 A, 240 VAC, NO contact, 85°C, VDE/UL508
5x10
4
RT31L
21/3.5 A, 230 VAC, compressor, cos
ϕ=0.5, NO contact
2,3x10
5
Coil data, DC-coil
Rated coil voltage range DC coil
5...110 VDC
Coil power DC coil
typ 400 mW
Operative range
2
Coil insulation system according UL1446
class F
Coil versions, DC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
c
mW
012
12
8.4
1.2
360+
+10%
400
024
24
16.8
2.4
1440+
+10%
400
048
48
33.6
4.8
5520+10%
417
060
60
42.0
6.0
8570+12%
420
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
Other coil voltages on request