TE Connectivity RT314F06 PCB Mount Relay 6Vdc 16A 1 CO, SPDT 8-1393239-6 Hoja De Datos
Los códigos de productos
8-1393239-6
Datasheet
Rev. FE1
Issued 2006/05
www.tycoelectronics.com
www.schrackrelays.com
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
change.
General Purpose Relays
1
Power PCB Relay RT1 bistable
I
1 pole 16 A, 1 CO contact
I
Polarized bistable version with 1 or 2 coils
I
5 kV / 10 mm coil-contact
I
Reinforced insulation
I
RoHS compliant (Directive 2002 / 95 / EC)
as per product date code 0413
as per product date code 0413
Applications
Battery powered equipment or applications with
"memory function”
"memory function”
F0176-B
Approvals
V
REG.-Nr. 6106,
Z
E214025
Technical data of approved types on request
Contact data
Contact configuration
1 CO contatct
Contact set
single contact
Type of interruption
micro disconnection
Rated current
16 A
Rated voltage / max.switching voltage AC
240/400 VAC
Limiting continuous current
20 A
Maximum breaking capacity AC
4000 VA
Limiting making capacity, max 4 s, duty factor 10%
30 A
Contact material
AgNi 90/10
Mechanical endurance
> 5 x 10
6
cycles
Rated frequency of operation with / without load
6 / 1200 min
-1
Contact ratings
Type
Type
Load
Cycles
RT314
20 A, 250 VAC, NO contact, 85°C, UL508
6x10
3
RT314
Pilot duty A300 (NO contact), B300 (CO/NC contact), UL508
RT314
1hp @ 240 VAC, 1/2hp @ 120 VAC, NO contact, UL508
Coil data
1 coil
2 coils
Rated coil voltage range DC coil
5...24 VDC
Coil power
typ 400 mW
typ 600 mW
Operative range
2
Limiting voltage, % of rated coil voltage
120%
150%
Minimum energization duration
30 ms
Maximum energization duration
1 min at < 10% DF
Coil insulation system according UL1446
class F
Coil versions, bistable coil
Coil
Rated
Operate
Reset
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
c
mW
bistable, 1 coil
A05
5
3.5
3.5
62+10%
403
A06
6
4.2
4.2
90+10%
400
A12
12
8.4
8.4
360+
+10%
400
A24
24
16.8
16.8
1440+
+10%
400
bistable, 2 coils
F05
5
3.5
3.5
42+10%
595
F06
6
4.2
4.2
55+10%
655
F12
12
8.4
8.4
240+
+10%
600
F24
24
16.8
16.8
886+
+10%
650
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
Other coil voltages on request