6. Commands  description 
6.1. Generic 
APDU 
 
6.1.1.  Working with DESFire and MIFARE Plus tokens 
 
To work with DESFire EV1 and MIFARE Plus tokens, please refer to the according application 
notes [AN337] and [AN338], respectively. 
Please note that, since these application notes contain information available only under NDA 
with NXP, you’d need to sign an NDA with NXP to be allowed to receive them. 
 
6.1.2. PAPDU_GET_UID 
 
GET UID will retrieve the UID or SNR or PUPI of the user token. This command can be used 
for all supported technologies. 
Command APDU
CLA 
INS 
P1 
P2 
Lc 
Data in 
Le 
0xFF 
0xCA 
0x00 
0x00 
XX 
Setting Le = 0x00 can be used to request the full UID or PUPI is sent back.(e.g. for ISO14443A 
single 4 bytes, double 7 bytes, triple 10 bytes, for ISO14443B 4 bytes PUPI). 
Response APDU: 
Data 
Status Word 
Requested bytes of UID 
SW1, SW2 
 
6.1.3. PAPDU_ESCAPE_CMD 
 
Usually escape commands are transmitted through SCardControl as defined in PCSC API 
using IOCTL_CCID_ESCAPE. But on some environments, the driver will block this IOCTL 
unless the registry has been edited to allow it. Hence this vendor specific APDU was defined to 
transmit Escape commands to the reader as below 
Command APDU
CLA 
INS 
P1 
P2 
Lc 
Data in 
Le 
0xFF 
0xCC 
0x00 
0x00 
Length 
of data 
Escape 
Command 
Buffer 
XX 
 
Response APDU: 
Data 
Status Word 
Reader Response 